Chapter 4---Maintenance (Removal/Replacement)
Model 100 Service Manual
Figure 4-16
CRT/ ILA
®
connections.
4.18 Projection Lens
To remove the Projection Lens
1.
Remove the Front Cover (Section 4.2).
2.
Remove the sponge cover from around the front of the Projection Lens.
3.
Disconnect the Projection Lens Focus, Position, and Zoom motor cables
(for Zoom Lens). The connectors for these motors are marked F, P, and Z,
respectively.
4.
Remove the 3 mounting bolts (3mm) on the Lens Support Bracket (see
Figure 4-17).
CAUTION!
Cradle the Front Lens with one hand
while removing the last 2 bolts so that it does not fall and get
damaged or damage other components in the projector.
5.
Replace the Projection Lens in reverse order.
6.
When changing from a Zoom Lens to a 1:1 Wide Angle Lens the
installation is the same as the removal as stated above. When changing
from a Zoom or 1:1 Wide Angle to a 1.5:1 (with offset), or vice versa, the
Lens Support Bracket must be changed. The appropriate Lens Support
Bracket will come with the Projection Lens.
7.
Remove the Lens Support Bracket by removing the 4 hex-head mounting
bolts (4mm).
NOTE:
To remove one of the bottom mounting bolts, it may be necessary
to remove the Arc Lamp Air Duct. Remove the 2 Phillips-head screws and
lift the Air Duct and pull out.
Yoke Cable
disconnect at
Vert/Conv
Deflection PCB
CRT Anode
Disconnect
CRT Focus
Disconnect
Summary of Contents for 100
Page 12: ...Chapter 1 Introduction 1 4 Model 100 Service Manual ...
Page 63: ...Chapter 2 System Description Model 100 Service Manual 2 51 ...
Page 67: ......
Page 115: ...Chapter 5 Troubleshooting Model 100 Service Manual 5 11 Various Problems ...
Page 117: ...Chapter 5 Troubleshooting Model 100 Service Manual 5 13 ...