Chapter 3---Service Adjustments
3-6
Model 100 Service Manual
3.
Use a clamp-on type ammeter such as AMPROBE Model AC/DC 1000, or
equivalent, and measure the Arc Lamp current around the Ignitor cable.
Place the clamp-on current meter around either end of the white cable that
goes from the Ignitor to the Arc Lamp and measure the current going to the
lamp (see Figure 3-3).
Figure 3-3
Arc Lamp current adjustment.
Figure 3-4
Zoom view of aperture on top of Arc Lamp Power Supply cover.
5.
Multiply the voltage by the current. The result should be 750 ±25 watts.
6.
If the result is not 750 ±25 watts, adjust the trimmer pot (see Figure 3-4)
until the result is 750 ±25. If increasing the current, observe that the voltage
may increase slightly.
7.
Wait approximately 10 minutes, then recheck the current and voltage and
make final adjustments, if necessary. Leave the front cover off to perform
the Arc Lamp Alignment procedure.
Arc Lamp
Power
Supply
Arc Lamp
Output ±
Terminals
Place DVM
leads here
Igniter leads
Summary of Contents for 100
Page 12: ...Chapter 1 Introduction 1 4 Model 100 Service Manual ...
Page 63: ...Chapter 2 System Description Model 100 Service Manual 2 51 ...
Page 67: ......
Page 115: ...Chapter 5 Troubleshooting Model 100 Service Manual 5 11 Various Problems ...
Page 117: ...Chapter 5 Troubleshooting Model 100 Service Manual 5 13 ...