Chapter 3---Service Adjustments
3-18
Model 100 Service Manual
2.
Reinstall the System Controller/ Raster Timing Generator PCB.
Figure 3-12
DIP Switches on SC/ RTG PCB.
3.
Apply power to the projector.
4.
In the Main Menu, go to System.
5.
In System, go to Comm Setup.
6.
In Comm Setup, go to Port A Device.
7.
In Port A Device, go to ANSI Terminal and select OK.
8.
Press ESC.
9.
Power off the Projector.
10.
Cycle off the A/C Main Circuit Breaker. This serves to reset the software.
11.
Insert a small screwdriver into the Service Mode Switch Access hole on on
the SC/RTG PCB (see Figure 3-13). Depress and hold down the Service
Mode Switch. While holding down the switch, turn the projector A/C
circuit breaker on.
Figure 3-13
Service Mode Switch access hole.
Service Mode
Switch Access
Hole.
DIP Switches
on SC/RTG
(makes sure all
the switches
are up)
ON
1
2
3
4
UP
Summary of Contents for 100
Page 12: ...Chapter 1 Introduction 1 4 Model 100 Service Manual ...
Page 63: ...Chapter 2 System Description Model 100 Service Manual 2 51 ...
Page 67: ......
Page 115: ...Chapter 5 Troubleshooting Model 100 Service Manual 5 11 Various Problems ...
Page 117: ...Chapter 5 Troubleshooting Model 100 Service Manual 5 13 ...