I.

Warning

Design and manufacture of the instrument and testing achieves IEC61010 safety
standards (electronic measuring product safety requirements), this manual including the
safety of the instrument use and ensure the safety of equipment state, users must follow
the warnings and safety regulations Please read the following instructions before use.

Warning

● Instrument output voltage, before use, read and understand the instructions of
operational guidelines.
● Please take manual save you to check at any time.
● Must be instructed to use the instrument.
● Understand and comply with the safety operating instructions.
Must strictly abide by the above instructions.
If you don't comply, measurement may cause personal injury and equipment damage.

Dangerous

(for improper operation can lead to serious or fatal damage)

● Before use, please wear insulated gloves.
● Please do not over AC/DC600V measurement circuit.
● Please do not test in flammable places, spark could cause an explosion.
● please do not hand wet or damp operators in instrument surface operation.
● Please don't charged the connection test line low.
● Low in the measurement, or do not touch the circuit being measured immediately after
the test, may result in electric shock accidents.
● Low test line or port found easy to damage the insulation properties of dirt or carbon
please stop test.

Warning

(for improper operation exists the possibility of a severe or fatal damage)

● If the instrument is abnormal, please stop using it. For example: instrument damage or
bare metal parts.
● Please do not install in the device replacement parts or any unauthorized modification,
maintenance, please contact with me.
● Make sure all wires and instrument testing port connection is firm.

Note

(for improper operation may cause personal injury or equipment damage)

Squared before measurement, confirm the voltage selection in the appropriate value.

If long time not to use, the battery should be fully charge, and recharge in 3 months.

Squared do not in high temperature, damp, places and condensation may be placed
under direct sunlight for a long time.

Please use a damp cloth or cleaner to clean the equipment enclosure, do not use
abrasives or solvents.

Instrument wet, please dry storage first.

Summary of Contents for HZJY-20K

Page 1: ...HZJY 20K Insulation Resistance Tester User Manual Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...l and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this instr...

Page 3: ...Contents I Warning 1 II Feature 2 III Specification Parameter 2 IV Introduction of instrument 3 V Instrument using 6 VI Packing List 7...

Page 4: ...erators in instrument surface operation Please don t charged the connection test line low Low in the measurement or do not touch the circuit being measured immediately after the test may result in ele...

Page 5: ...ion batteries battery life can be up to 4 hours 10000V 100M Insulation resistance simulation column Digital filtering functions external influence deviation display value causing mitigation point usi...

Page 6: ...1T 2T range accuracy 15000V 20000V Unspecified 1M 1M 5 1M 300G 1M 400G 20 300G 3T 400G 4T Unspecified 3T 4T IV Introduction of instrument The Front Panel Description number Description number Descrip...

Page 7: ...case recommended 1 hardware low pass filter applicable to most situations 2 software Low pass filter High resistance greater than 100G recommended choose 3 hardware software low pass filter high resis...

Page 8: ...to determine the current Settings and exit Help menu system HELP Record the serial number of product production date version information Insulation testing interface Digital Insulation value greater t...

Page 9: ...opped display shows as shown in the table of the soft keys Soft key Description OFF Power Off No operation 3 minutes automatic shutdown Back Return to the main menu H V Set test voltage Manual 500V 10...

Page 10: ...een When measuring high insulation resistance the sample should be in the position a conductor surface protection between the two measuring end ring and the conductor protection ring is connected to t...

Reviews: