HZ2363 Three Phase Contact Resistance Tester is made and contained of advanced
high-power switching power supply technology and advanced electronic circuit. It is the
dedicated tester for the resistance of high and low switch, cable wire and welding joint. Its
current uses national standard GB736 recommended standard DC, can measure the
resistance value of being tested object under standard current status. The tester is small
dimension, light weight, strong anti-interference, high precision, easy operation and perfect
function protection and so on.

II.Product Features

1.Color Touch Screen: 800*480 high resolution color 7’’ touch screen, user interactive

interface, high-speed thermal printer.

2.Large-range current output

Adopt the latest power supply technology, long time

continuously output big current, large-range current output. Can set 1 to 3 different current

range for testing, and automatically calculate average value.

3.Digital displaying data information

Resistance, voltage, current, electrical resistivity

resistance values at converted standard temperatures.

4.Auto-alarm of over limit

Set resistance up-limit value of pass / over limit / invalid,

automatically generate testing status.

5.Long-time testing: Can set test time from 0-9999s and support long-time working. Inside

cold-wind heat dissipation, switch power automatically protection.

6.High-precision measurement: Use Operational amplifiers from precision instruments and

High precision quadruple integral A/D converter.

7.Latest System IC

Use High performance 32-bit latest ARM chips, System automatically

switch magnification times based on signal, ensure testing precision.

8.Inside Calendar & Clock

provide accurate time of testing and printing.

9.DC constant current source function

Can output current from 0 to infinite value, built-in

current step-by-step up-flow test, equal to another powerful DC constant current source for

test.

10. Large-volume testing record storage

Build-in large capacity storage for look up, also have

data protection function while power shut down suddenly.

11. Removable USB flash drive data access

Expert word file data record.

12. Standard Modbus-RTU: Build-in RS232 port (customized convert to RS485),

communication protocol Modbus-RTU.

13. Blue tooth control and upload data

Standard configuration blue tooth function, build-in

android BT APP for data control / upload / generate word file.

14.Convenient cable operating

Cable control mode (customized), set cable control switch to

regulate open / touch, test / interruption, light-alarm for resistance output over limit.

14.Quick and convenient wireless remote controller

it is customized, with one button

operation of testing and interruption, customized controller can show the test progress.

15.Temperature offset automatically calculate resistance

Can preset temperature,

automatically calculate resistance in standard temperature. Also use temperature sensor

(customized) to measure.

16.Background color change: Set background color to blue and graphic black, brightness,

standby brightness and time.

17.Build-in training material

Document shows the cable connecting method for onsite

Summary of Contents for HZ2363

Page 1: ...HZ2363 Three Phase Contact Resistance Tester Huazheng Electric Manufacturing Baoding Co Ltd ...

Page 2: ...anual and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this instrument If you are satisfied with this instrument please tell your colleagues if you are not satisfied with this instrument please call 0312 6775656 to tell you to serve you at all times Baoding Hua...

Page 3: ...iple 2 V Panel Description and Wire Connection 4 VI Operating Procedure 5 VII DC Constant Current Source Function 12 VIII Mobile Phone Control and Data Transfer BT communication 12 IX Failure Analysis and Trouble Shooting 14 X Attentions 14 XI Transportation and Storage 14 XII Packing list 15 ...

Page 4: ...sion quadruple integral A D converter 7 Latest System IC Use High performance 32 bit latest ARM chips System automatically switch magnification times based on signal ensure testing precision 8 Inside Calendar Clock provide accurate time of testing and printing 9 DC constant current source function Can output current from 0 to infinite value built in current step by step up flow test equal to anoth...

Page 5: ... customized 20A 50A 100A 150A 200A 300A 400A customized 20A 50A 100A 150A 200A 300A 400A 500A customized 20A 50A 100 A 150 A 200 A 300 A 400 A 500 A 600 A cust omiz ed Current customize d 1 two phase 2 three phas e Test range 0 19999 expandable Test precision 0 5 rdg 10dgt Resolution 0 01 Working power AC 220V 10 50Hz 2 Length m m 450 450 Width mm 250 250 Height mm 220 280 Weight Kg 9 9 12 9 Envir...

Page 6: ...rce have two end I I called I shape supply current for being tested resistance Rx current value can be read by amperemeter I voltage of Rx V V called V shape read by voltmeter V So to calculate resistance value by the measurement of I and V ...

Page 7: ...gative Three phase connecting post is separately for A B and C A is yellow B is green C is red Touch color screen 800 480 pixel dot matrix touch color LCD screen very visible under sunshine and dark environment Thermal printer Build in a thermal printer in the tester Thermal paper can be used for data printing on one side can not on the other side Only around three months recording on the thermal ...

Page 8: ...ded with product shipment VI Operating Procedure Normal operating process is shutdown cable connection power on settings test data storage printing shutdown and remove cable totally it is 7 setp 1 Cable connection Under shutdown status please connect GND cable power cable test cable Refer to the cable connection diagram in help menu Tighten the big current clamp small current clamp must tight touc...

Page 9: ...d normal temperature resistance average value converted normal temperature resistivity average value Left down parameters zone Set three output current range test time resistance up limit alarm value being tested resistance length and section area Right down test zone 1 three buttons stands corresponding each test data of three current range Green stands for having data black shows no data Selecte...

Page 10: ...ters in system not impact by power off and re open Current test times and output current In the interface to set current times stands for different current range to calculate average value can select I1 I1 I2 I1 I2 I3 I1 is only for output I1 current test I1 I2 is for output I1current test first and then output I2 current test I1 I2 I3 is for output I1 current test first then output I2 current tes...

Page 11: ... select stop actual temperature is preset temperature If select customized temperature sensor and select start actual temperature is real in testing Background selection and traditional and simplified forms of Chinese characters Set screen color to image text blue and black If select simplified then do not show converted data in main interface Test remark Press test remark button to enter picture ...

Page 12: ...a Thermal paper can be used for data printing on one side can not on the other side Only around three months recording on the thermal paper not for long time storage 7 Document open and management In the main interface press open menu of function menu to enter interface as picture 9 Picture 9 The interface shows page number total number and selected item document name is called by real time Click ...

Page 13: ...ar to clear out all files Insert U disk then show U disk inserted reminding press export to convert file to WORD inside U disk Already exported file shows UP means not be re exported see picture 11 Picture 11 File named by test real time and store as picture 12 ...

Page 14: ...ground brightness idle time and brightness of idle Cable connection diagram guide and train onsite operating of cable connection Time settings calibrate system time of tester Maintenance Factory enter the page to key in password to do maintenance Unser is not allowed enter it Related picture 13 14 Picture 13 Picture 14 ...

Page 15: ... up current process Firstly take initial current value output keep timing to periodical time value then add step current value output Again keep timing to periodical time value and then add step current value output repeat the cycling process to output current over max current value finally finish the whole output current In the test can press interruption to stop whole test process VIII Mobile Ph...

Page 16: ... in password 1234 to connect it Connect blue tooth successfully then use APP to control tester Like click test stop upload store etc after upload and store picture 23 25 shows Picture 23 Picture 24 File is stored in data catalog and named by real test time for convenient storage report generation and data sharing ...

Page 17: ...ture proof dry and clean room 3 Do not disassemble and revise the tester or else caused electric shock risk 4 Do not repair and self revise or else it is not the guarantee period 5 Do read the user manual in details before using XI Transportation and Storage Transportation While transport product recommend use our provided package wooden case and damping stuff in case of damage during delivery los...

Page 18: ...15 XII Packing list NO Name Quantity 1 Black Test Line 3 2 Power Line 1 3 Print Paper 1 4 Black Test Line 3 5 Ground Lead 1 6 Fuse 2 ...