Doc No. FM0614 issue D Page 1  

169MHz Telecare Devices 

Enuresis Sensor & Cotton Bed Sheet 

 

__________________________________________________________________________________________________________ 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compatible with Reach at-home alarms, Advent xt warden call,  
Altec Response and Touchsafe Pro Nursecall systems 

 

Interface unit complete with cotton bed sheet & lead 

 

Cotton bed sheet dimensions: 1.2m x 0.9m  

 

Connecting lead with press stud fixings: 2m long  

 

Interface unit with user replaceable 9V battery 

 

Low battery warning  

 

Interface dimensions: 90 x 65 x 28 mm (HxWxD) 

 

Interface weight: 170 grams 

 

Product Code: ZXT476 

 

Replacement cotton sheet: Part No. W00860   

 

Replacement lead: Part No. W00861 

 

 

 

 

 

 

 

 

Where should Enuresis Sensors be located? 

 

The cotton sheet should be placed between the bottom sheet and the mattress to detect instances of enuresis.   
An alarm will be raised immediately moisture is detected thereby alleviating carers from making regular checks which can be 
intrusive and unwelcome. 

 

 

Installation 

 

It is easier to register the Enuresis sensor before installation 

 see below. 

 

1.

 

Remove the bottom sheet from the bed. 

 

2.

 

Place the cotton sheet across the width of the bed at a point where  
the pelvic area of the person will be when lying down. 
The side with the visible pattern of electrodes should be placed uppermost 
with the press stud connections accessible. 
If necessary a towel can be placed over the sheet to make it less sensitive.

 

 

3.

 

Connect the lead to the cotton sheet using one of the pairs of press studs  
(i

t doesn’t matter which), see image below

 

4.

 

Ensure the wire exits safely without causing a hazard. 

 

5.

 

Refit the bottom bed sheet. 

 

6.

 

Remove the battery cover from the interface unit and connect the battery. 

 

7.

 

Plug the lead into the interface unit and make sure it is placed safely  
out of the way under the bed.   

 

 

Testing and Registering the Enuresis Sensor 

 

Place a metal object across the 2 un-used press studs  
on the cotton bed sheet to activate an Enuresis alarm. 

 

The Enuresis sensor must be activated when learning 
onto the warden call, at-home alarm or Nursecall system. 

 

 

 

 

See the following pages for how to put each of these  
products into registration mode.  

 

The range of all radio devices can be affected by the working environment - always take care during installation and 
perform several test calls. 

 

 
 
 
 
 
 

 

CONNECT LEAD 
TO ONE PAIR OF 
PRESS STUDS 

SHORT-OUT THE 
OTHER PAIR OF 
PRESS STUDS  
TO TEST  

Tynetec and Aidcall are business units of Legrand Electric Ltd 

Unit 10 Cowley Road, Blyth Riverside Business Park, Blyth 

Northumberland, NE24 5TF. Tel: 

01670 352 371

 

Email: 

[email protected]

 Web

www.tynetec.co.uk

 

Summary of Contents for tynetec Aidcall

Page 1: ...e person will be when lying down The side with the visible pattern of electrodes should be placed uppermost with the press stud connections accessible If necessary a towel can be placed over the sheet to make it less sensitive 3 Connect the lead to the cotton sheet using one of the pairs of press studs it doesn t matter which see image below 4 Ensure the wire exits safely without causing a hazard ...

Page 2: ...xpect a reduced life of 30 washes Do not use a fabric conditioner this will make the sheet waterproof If the sheet develops brown staining around the electrodes consult the manufacturer for cleaning instructions Maintenance The Enuresis sensor should be activated periodically to check the electrodes in the cotton sheet have not been damaged in the wash see Testing and Registering on page 1 Replace...

Page 3: ...nt light will return to STEADY GREEN The 8 digit ID can be found on a label on the back of the Enuresis interface unit it will always start with 32xxxxxx The instructions given above for the standard Reach product also applies to the Reach Plus Reach Plus GSM and Reach Ultra models Refer to the instruction booklets provided with these products for more information on programming and testing radio ...

Page 4: ...r the connection Refer to the Advent xt operator s manual Doc No FM0420 provided with the warden call system for more information on programming and testing radio devices Using the Manager s DECT telephone Press the LINE key and wait for the Ready prompt Enter 5 0 0 0 followed by the key Enter the flat number the Enuresis sensor is being installed in followed by the key You now have 1 minute to ac...

Page 5: ...ng and testing radio devices Short out the 2 un used metal press studs on the cotton bed sheet The display will show Enuresis and the enuresis sensor 8 digit ID number Check the ID is correct press the key to select Accept then press ENTER Note if another device has been picked up press ENTER to Reject and try again The display will show Flat use the keys to choose the dwelling type Press the key ...

Page 6: ...ith a T32 Details of the Enuresis sensor selected will be displayed in the Room House Code and ID boxes below If the details shown are correct press the Delete button Press the Close button to exit Refer to the Touchsafe Pro Display Panel user guide Doc No FM5505 provided with the Nursecall system for more information Tynetec and Aidcall operate a policy of continuous improvement and reserve the r...