Paramet
er
Descripti
on
Value
<option>
Serial
port
direction
The value options of this parameter and the value
meanings vary according to the server model. You
are advised to run the ipmcget -d serialdir
command to view the value options.
For the server, the options are as follows:
– 0: sets the serial port on the server panel as the
system serial port.
– 1: sets the serial port on the server panel as the
iBMC serial port.
– 2: sets the SOL port as the system serial port.
– 3: sets the SOL port as the iBMC serial port.
– 4: sets the serial port on the SDI V3 card panel as
an SCCL port.
– 5: sets the serial port on the SDI V3 card panel as
an IMU port.
– 6: sets the serial port on the SDI V3 card panel as
an SCCL port.
– 7: sets the serial port on the SDI V3 card panel as
an IMU port.
To set the panel serial port as the iBMC serial port,
run the ipmcset -d serialdir -v 1 command.
NOTE
– If no SDI V3 is installed in a server, <option> can be 0
to 3 only.
– If one SDI V3 card is installed, the values 4 and 5 are
available for setting the ports on the SDI V3 in I/O
module 1 or 2.
– If two SDI V3 cards are installed, the values 4 to 7 are
available. The values 4 and 5 are used for setting the
ports on the SDI V3 in I/O module 1, while the values 6
and 7 are for the ports on the SDI V3 in I/O module 2.
●
To set the serial port by using a jumper, do as follows:
a. Power off the server and remove the power cables.
b. Place the jumper cap on COM_SW pins. For details about the jumper
position, see Mainboard and iBMC Card Connectors in the
Server Maintenance and Service Guide (Model 2280)
c.
Connect the power cables and power on the server.
Step 2 Use a serial cable to connect the terminal serial port and the server serial port.
Step 3 Open HyperTerminal and set the following parameters:
●
Bits per second: 115200
●
Data bits: 8
TaiShan 200 Server
User Guide (Model 2280)
8 Common Operations
Issue 04 (2020-01-16)