SUN2000-(3.8KTL-11.4KTL)-USL0
User Manual
4 System Installation
Issue 01 (2018-05-21)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
21
Category
Tools and Instruments
PPE
Safety gloves
Safety goggles
Anti-dust respirator
Safety shoes
N/A
N/A
4.3 Determining the Installation Position
Basic Requirements
The SUN2000 is protected to TYPE 4X/IP65 and can be installed indoors or outdoors.
Do not install the SUN2000 in a place where people are likely to come into contact with
its enclosure and heat sinks, because these parts are hot during operation.
Do not install the SUN2000 in areas with flammable or explosive materials.
Install the SUN2000 in a place out of reach of children.
The SUN2000 is vulnerable to salt corrosion, and this may cause fire. Do not install the
SUN2000 outdoors in salt areas. A salt area refers to the region within 500 meters from
the coast or prone to sea breeze. The regions prone to sea breeze vary depending on
weather conditions (such as typhoons and monsoons) and terrains (such as dams and
hills).
Installation Environment Requirements
The SUN2000 must be installed in a well-ventilated environment to ensure good heat
dissipation.
When the SUN2000 is installed under direct sunlight, its power may decrease due to the
rise in temperature.
Mounting Structure Requirements
The mounting structure where the SUN2000 is installed must be fireproof.
Do not install the SUN2000 on flammable building materials.
Ensure that the installation surface is flat and sturdy enough to bear the weight load.
In residential areas, do not install the SUN2000 on drywalls or walls made of similar
materials which have a weak sound insulation performance, as the noise generated by the
SUN2000 is noticeable.