SUN2000-(3.8KTL-11.4KTL)-USL0
User Manual
7 Operations on the Local FusionHome App
Issue 01 (2018-05-21)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
106
Figure 7-43
Feature parameters
The feature parameter values vary with the grid code.
Table 7-10
Description of feature parameters
Parameter
Description
Value Range
MPPT multi-peak scanning
When the SUN2000 is used
in scenarios where PV
strings are obviously
shaded, enable this function.
Then the SUN2000 will
perform MPPT scanning for
all PV strings at regular
intervals to locate the
maximum power.
The scan interval is
specified by
MPPT
multi-peak scan interval
.
Disable
Enable
MPPT multi-peak scan
interval (min)
Specifies the MPPT
multi-peak scanning
interval.
This parameter is displayed
only when
MPPT
multi-peak scanning
is set
to
Enable
.
[5, 30]