S1700 Managed Series Ethernet Switches
Web User Manual
4 Interface Management
Issue 05 (2012-10-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
30
Item
Description
Collision on the Interface
Total collision packets transmitted on this interface.
Giants Error Packets
Total Giants error packets transmitted on this interface.
CRC Error Packets
Total CRC error packets transmitted on this interface.
Aborts Error Packets
Total Aborts error packets transmitted on this interface.
Details of Statistics on Interface
Step 1
Click Interface Management > Ethernet Interface > Statistics on Interface.
Step 2
Choose the check box in the left-hand column of the interface to be viewed for details from
the list, and then click Details button to view the detailed statistics data of designated interface,
the configuration page is shown as the figure below.
Figure 4-4
Details of Statistics on Interface
Step 3
Click Close, to return to the configuration page of Statistics on Interface.
----End
4.2 Eth-Trunk
This section describes a method to configure Eth-Trunk.
User is allowed to set up multiple links among multiple switches. Link Aggregation is a
method of binding a group of physical interfaces as a logical interface to increase bandwidth.
At most 12 manual Trunks and static LACP can be set up at the same time.
This device supports manual Trunk and link aggregation control protocol (only supports static
LACP). Manual Trunk needs a manual setting of links at both ends, and must be compatible
with Cisco EtherChannel standard. On the other hand, a Trunk link can be connected between
the LACP interface of a device and that of another device. User is allowed to configure any
member with an interface number of LACP as long as these numbers are not configured as