Table 11-3
Parameters of Information Center
Item
Description
Log State
Select Enable to enable system log, and select Disable to disable
system log. The default is Enable.
Buffer Log Level
Buffer Log Level is divided into eight levels, and the information
can be filtered on basis of the levels. The smaller the value level of
system information, the higher the degree of urgency should be.
For the detailed severity level, please refer to 11-4 Severity Level
List.
Trap Log Level
Trap Log Level is divided into eight levels, and the information can
be filtered on basis of the levels. The smaller the value level of
system information, the higher the degree of urgency should be.
For the detailed severity level, please refer to 11-4 Severity Level
List.
Device
Select a device that sends out the system information.
Source IP Interface
Select source IP interface of device used to send system
information.
Log File Write Delay
Refers to the interval used to save FLASH. If the interval is 0
(means unlimited time), it should be saved to FLASH manually; if
the interval is 1-65535, the system will be saved to FLASH
automatically according to the entering interval (in minutes).
Log Server
User can add log server.
Table 11-4
Severity Level List
Severity Code
Numerical
Description
emergencies
0
System is unusuable
alerts
1
Action must be taken immediately
critical
2
Critical conditions
errors
3
Error conditions
warnings
4
Warning conditions
notifications
5
Normal but significant condition
informational
6
Informational messages
debugging
7
Debug-level messages