7 Installing the RRU
Issue Draft B (2018-05-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
68
Figure 7-29
Top view of an RRU
(1) Angle steel
Procedure
Step 1
Determine a position for installing the mounting kits.
If the RRU is installed on angle steel secured on a tower, determine a position for
installing the mounting brackets according to the instructions in 3.5.1 Clearance for a
Single RRU.
If the RRU is installed on angle steel secured on the ground, determine a position for
installing the mounting brackets according to Figure 7-30.
Figure 7-30
Distance between the mounting kits and the ground
As shown in the figure above, it is recommended that the mounting kits be installed at a position 1200
mm (47.24 in.) to 1600 mm (59.06 in.) high above the ground. If the space is insufficient, only the 3.5
Installation Clearance Requirements of an RRU needs to be provided.
Step 2
Install the RRU mounting kits, as shown in Figure 7-31.