RRU5303
Installation Guide
8 Installing RRU Cables
Issue Draft B (2018-05-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
99
Cable
One End
The Other End
Connector
Installation
Position
Connector
Installation
Position
Optic Cable
the RRU
board in the
BBU or CPRI1
port on the
upper-level
RRU
CPRI1 port on
the RRU
CPRI0 port on
the lower-level
RRU or CPRI
port on a board
in the BBU
RRU RF
Jumper
4.3-10 straight
male connector
RF ports on
the RRU
4.3-10 straight
male connector
or DIN male
connector
NOTICE
Select cables
based on the
type of the
connector at the
other end of the
cable on live
networks.
Antenna system
RRU AISG
Multi-Wire
Cable
DB9 waterproof
male connector
RET port on
the RRU
Standard AISG
female
connector
Standard AISG
male connector
on the RCU or
on the AISG
extension cable
RRU AISG
Extension Cable
Standard AISG
male connector
Standard
AISG female
connector on
the AISG
multi-wire
cable
Standard AISG
female
connector
Standard AISG
male connector
on the RCU
8.5 Installing an RRU PGND Cable
This section describes the procedure for installing an RRU PGND cable.
Context
The cross-sectional area of an RRU PGND cable is 16 mm
2
(0.025 in.
2
). The cable has an M6
OT terminal at one end and an M8 terminal at the other end.