Figure 8-7
Securing the captive screw into the connection hole
----End
8.2.2 Installing Two RRUs
This section describes the procedure and precautions for installing two RRUs on a pole.
Prerequisites
The hoist clamp on the main bracket is secured properly.
NOTICE
l
Do not stand the RRU upright because the RF ports cannot support the weight of the RRU.
l
Place a foam pad or cardboard under the RRU to protect the RRU housing from damage
during the installation.
Procedure
Step 1
Install the first RRU onto the main bracket, as shown in
.
RRU3832&RRU3632
Installation Guide
8 Installing the RRU
Issue 05 (2014-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
56