, two NM stations (NMS1 and NMS2) and the router are connected
across a public network. According to the network planning, NMS2 can manage every MIB
object except HGMP on the router, and NMS1 does not manage the router.
On the router, only the modules that are enabled by default are allowed to send alarms to NMS2.
This prevents an excess of unwanted alarms from being sent to NMS2. Excessive alarms can
make fault location difficult. Informs need to be used to ensure that alarms are received by NMS2
because alarms sent by the router have to travel across the public network to reach NMS2.
Contact information of the equipment administrator needs to be configured on the router. This
helps the NMS administrator to contact the equipment administrator if a fault occurs.
Figure 3-8
Networking diagram for configuring a device to communicate with an NM station
by using SNMPv2c
1.1.2.1/24
GE1/0/0
Router
1.1.1.1/24
1.1.1.2/24
NMS2
IP Network
NMS1
Configuration Roadmap
The configuration roadmap is as follows:
1.
Enable the SNMP agent.
2.
Configure the router to run SNMPv2c.
3.
Configure an ACL to allow NMS2 to manage every MIB object except HGMP on the
router.
4.
Configure the router to send informs to NMS2 to ensure alarm sending reliability.
5.
Configure the contact information of the equipment administrator.
6.
Configure NMS2.
Data Preparation
To complete the configuration, you need the following data:
l
SNMP version
l
Community name
l
ACL number
l
IP address of the NM station
l
Contact information of the equipment administrator
HUAWEI NetEngine5000E Core Router
Configuration Guide - System Management
3 SNMP Configuration
Issue 01 (2011-10-15)
Huawei Proprietary and Confidential