Figure 5-2
Minimum space requirements of the pRRU
When the external antenna is not required, the minimum space for installing a single pRRU is
described as follows:
l
At least 50 mm above the pRRU is reserved for maintenance.
l
At least 150 mm under the pRRU is reserved for cabling.
l
At least 50 mm on the left of the pRRU is reserved for maintenance.
l
At least 50 mm on the right of the pRRU is reserved for maintenance.
l
At least 50 mm in front of the pRRU for maintenance.
l
At least 20 mm on the back of the pRRU is reserved for ventilation.
Extender Space Requirements
Only space above and under the Extender is required to be reserved when installing the Extender.
shows the recommended space requirements of the Extender.
Figure 5-3
Recommended space requirements of the Extender
LampSite
Installation Guide
5 Installing a pRRU
Issue 02 (2014-05-27)