Step 3
Power on the RHUB. Wait 3 to 5 minutes, check the status of the RUN indicator of the RHUB
after the RHUB runs properly.
If the Status of
the RUN
Indicator...
It Indicates that...
Then...
Steady on
The power supply is
normal while the board is
faulty.
Power off the RHUB, and power on it again
after rectifying the board fault.
Steady off
There is no power input
or the board is faulty.
Power off the RHUB, and check the power
input again. Rectify the board faulty and
power on the RHUB again if the power input
is normal.
On for 1s and off
for 1s
The devices work
properly.
End the operation.
On for 0.125s and
off for 0.125s
The board software is
being uploaded.
Power off the RHUB if the uploading is not
finished in 5 minutes, and check whether the
configuration file is correct. Power on the
RHUB again after the fault is rectified.
----End
LampSite
Installation Guide
4 Installing an RHUB
Issue 02 (2014-05-27)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
43