Hardware Installation
2
Installing Cabinet Hardware
2-10
c) Connect the grounding cable to the lightning protection zone on the
building-top.
II. Installation layout of an omni BTS3601C
As shown in Figure 2-6, the mast in middle is used to install the lightning arrester; while
in the rest two masts, the one being installed with BTS3601C is called master mast,
and the other is called slave mast.
1) Lightning arrester
2) Cabling Rack
3) Antenna
4) GPS antenna
5) IAFB
6) BTS3601C
Figure 2-6
Omni BTS3601C installation on metal masts
III. Installation layout of a directional BTS3601C
Figure 2-7 shows the installation of a directional BTS3601C cascaded with an
ODU3601C. The mast, on which the BTS3601C is installed, is called master mast, and
the one where the ODU3601C is instaled is called slave mast.