Installation Manual
iSiteC BTS3601C CDMA Base Station
Hardware Installation
2
Installing Cabinet Hardware
2-6
2.2.2 Example of Indoor Plinth Installation
Inside the equipment room, if BTS cannot be installed on the wall (e.g. structure pole,
hollow wall body, clapboard wall in the simplified equipment room), it can be installed
on the plinth. The position of the plinth should be as close to the wall as possible.
Figure 2-4 shows the indoor plinth installation of BTS with IAFB.
1) Front view
2) Side view
3) BTS3601C
4) IAFB
5) Indoor grounding bar
6) Support
7) Feeder window
8) Jumper
9) Protection grounding
10) BTS3601C PGND cable
11) IAFB grounding bar
12) Power cable
13) GPS feeder
14) Wall
Figure 2-4
Installing BTS3601C on the plinth
2.2.3 Example of Concrete Pole Installation
This installation mode applies to such environment as fields, villages, towns, road sides,
etc. to cover the locations like villages and towns. In this case, two poles must be used
in the installation no matter that the BTS to be installed is an omni BTS or a directional
one.
I. Facility requirements
l
The standard spacing between two poles should be 5m (not less than 3.5m at
least), and horizontal diversity distance between two antennae should be 6m (not
less than 5m at least). For an omni BTS, a metal mast should be used to meet the