NOTE
The method used to query the firmware version varies depending on the operating system:
–
For Linux and VMware ESXi 5.1 or earlier, run the
ethtool -i eth <value>
command to
check the firmware version: In the command,
<value>
indicates the port number.
ethtool -i eth <value>
–
For VMware ESXi later than 5.1, run the
esxcli network nic get -n vmnic <value>
command to check the firmware version: In the command,
<value>
indicates the port
number.
esxcli network nic get -n vmnic <value>
Step 13
Upgrade the firmware and driver to the latest versions.
You can obtain the latest firmware and driver versions from
.
l
For details about how to upgrade the firmware, see section "Upgrading Mezzanine
Cards" in
E9000 Server V100R001 Upgrade Guide
l
For details about how to upgrade the driver, see section "Installing Drivers and
Firmware" in
Huawei Server OS Installation Guide
.
----End
4.3.13 Removing a Processor
l
Only Huawei technical support or personnel authorized by Huawei can remove the
processors from Huawei servers.
l
Do not wear ESD gloves during processor replacement. The gloves may catch on pins on
the processor socket and damage it.
l
Intel heat sinks or Huawei-developed heat sinks are used, depending on the processor
cooling solution.
Procedure
Step 1
Power off the compute node.
Step 2
Remove the compute node.
Step 3
Place the compute node on the ESD workstation.
Step 4
Remove the cover.
.
Step 5
Remove the air duct.
.
Step 6
Check whether a PCIe card is installed.
FusionServer Pro CH121 V5 Compute Node
Maintenance and Service Guide
4 Parts Replacement
Issue 06 (2019-08-10)
Copyright © Huawei Technologies Co., Ltd.
73