MM910 Management Module V100R001 User Guide
–
On the MM910 CLI, run the following command:
powerstate
MM910 Management Module V100R001 Command Reference
.
The following describes how to power on a compute node using the MM910 WebUI.
Procedure
Step 1
Check that the chassis is installed, the power cables are correctly connected, and the PSUs and
fan modules are in position.
Step 2
Log in to the MM910 WebUI.
12.3 Logging In to the MM910 WebUI
.
Step 3
On the HMM WebUI, choose
PSUs&FANs
.
The
PSUs&Fans
page is displayed.
Step 4
Choose
PSU Management
>
Power Control
from the navigation tree.
Figure 3-2
Power Control
Step 5
Select the compute node to be powered on, and click
Power On
.
The selected compute node will be powered on.
NOTE
To power on all compute nodes at a time, select the check box in the header row and click
Power On
.
----End
3.3 Removing a CH121 V5
Procedure
Step 1
Determine the position of the compute node in the chassis.
FusionServer Pro CH121 V5 Compute Node
Maintenance and Service Guide
3 Basic Operations