2.5.3.
Checking the spark plugs
7. Check the electrode distance of
the spark plugs with the help of the
feeler gauge.
0,69 - 0,84 mm
[0.0272 - 0.0331 in.]
2.6. Valve play
2.6.1.
Checking and setting the valve play
IMPORTANT!!!
•
Hex wrench SW5 [3/16 “]
•
Feeler gauge, measurement range 0.08 mm - 0.25 mm [0.0031 - 0.0098 in.]
•
Valve adjustment tool, see spare parts catalogue
•
Combination wrench 24mm [15/16 “]
•
Bar
magnet
•
Measurement tool for adjustment plate, reading 0.01mm [0.0003 in.]
•
Adjustment plates from 2.5 - 3.7 mm [0.0984 - 0.1457 in.], see spare parts catalogue
•
Valve cover seals, see spare parts catalogue
•
2x O-rings, see spare parts catalogue
To get correct measurement values, check and adjust valve play with a cold engine.