Technical Data - Standard design
FM 169 A&M Instr. for Gamma type Z..D Rev.01
2018-06-11
7
distributed by
Forces and moments for Gamma linear unit with toothed belt drive
Type designation
Dynamic forces [Nm]
Dynamic moments [Nm]
F
X
F
Y
F
Z
-F
Z
M
X
M
Y
M
Z
M
idle
Gamma 90-ZSSD
1150
2500
3000
3000
500
800
700
2.90
Gamma 120-ZSSD
1800
6000
8000
8000
1200
1300
1100
3.00
Gamma 160-ZSSD
2200
10000
16000
16000
1800
5000
4000
4.00
Gamma 220-ZSSD
2800
12000
20000
20000
2500
8000
6500
5.25
Gamma 280-ZSSD
4000
20000
30000
30000
4000
15000
12000
11.00
M
idle
= Idle torque ±30%
The specified forces and moments are the respective maximum values for the single
load. The individual values must be reduced for a mixed load or the occurrence of
several moments or forces at the same time. If in doubt, please contact Technical
Support.
Dynamic load ratings for the Gamma ZSSD linear unit
(THK and Rex = Rexroth)
Unit size
Size No. of
rails
No. of
carriages
Load rating per
carriage
C
dyn
[N]
THK / Rex
Pretensioni
ng F
V
[N]
THK / Rex
Guiding distance
in direction x (lx1)
[mm]
Guiding distance
in direction y
(ly) [mm]
Gamma
90-ZSSD
15
2
4
11271 / 9860
564 / 620
75
73
Gamma
120-ZSSD
20
2
4
17700 / 23400
885 / 1500
80
90
Gamma
160-ZSSD
25
2
4
25160 / 28600
1258 / 1820
208
120
Gamma
220-ZSSD
25L
2
4
29208 / 37300
1460 / 2430
210
180
Gamma
280-ZSSD
35
2
4
49448 / 51800
2472 / 3350
275
236
The load rating and pretensioning values refer to the standard linear guide system
Summary of Contents for Gamma 120-ZSSD