10.2 Replacing the toothed belt
For optimum functioning of the linear unit and to prevent damage
during operation, it must be ensured during assembly that no
foreign matter enters any parts of the linear unit.
Do not damage the standard parts (screws, pins, etc.) as they will
be used again.
L
e
g
e
n
d
1
Bearing housing cover plate
5
Clamping screw
2
Synchronising disc
6
Toothed belt holder, compl.
3
Toothed belt
7
Carriages
4
Tensioning screws
8
Base profile
Figure 7: Replacing the toothed belt
1.
Loosen the clamping screws (5) on the toothed belt holder (6).
2.
Loosen the tensioning screws (4) on the toothed belt holder (6) on
both sides of the sliding carriage (7).
3.
Place both toothed belt holders on the basic profile (8).
4.
Unscrew the clamping plate from the toothed belt holders
(6 screws each).