- 50 -
4.8.2 Cleaning / replacement of the threaded mandrel
Loosen and remove the mouthpiece (1).
In order to clean or replace the threaded mandrel (2)
pull back the silver lock ring (3) and loosen the mandrel
by turning.
If the housing can not be loosened by hand it can be
loosened using two SW24 keys.
These components can be cleaned using a wire brush
or a cloth. Any shavings should be removed. Then check
the mandrel and replace if necessary.
Then reassemble the device in reverse order. While
doing so ensure that the threaded mandrel is again
locked into place flush with the lock ring.
4.8.3 Machine capability test (MCT)
We recommend an annual machine capability test for high quality standards and a long
life span. This can be combined with maintenance and inspection of the overall tool.
The machine capability test can be completed by HS-Technik GmbH.