Chapter 10 Parameter
Shenzhen Hpmont Technology Co., Ltd.
-72-
HD09 Series User Manual V1.1
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
Thousands: Switch the frequency
channel to the analogue selection
0: Not save
1: Save
F00.15
Jog operation frequency
digital setting
0.0 - up limitation (F00.08)
5.0Hz
0.1Hz
○
F00.17
Running direction
selection
0: Same direction
1:Reserved direction
0
1
×
F00.19
Dead time of direction
switch
0.0 - 3600.0s
0.0s
0.1s
×
F00.20
Keypad enbale
Unit: Button enbale
0: Enable
1: Disable
Ten: Potentiometer enbale
0: Potentiometer priority for keypad
1: Potentiometer with keypad
2: Potentiometer with external keypad
00
1
○
F00.21
Sleep function enbale
0: Disable
1: Enable 1
2: Enable 2
0
1
×
F00.22
Dormant wake time
0.0 - 360.0s
0.0s
0.1s
×
F00.24
Sleep delay
0.0 - 3600.0s
0.0s
0.1s
×
F00.25
Sleep frequency
0.0Hz - F00.08
0.5Hz
0.1Hz
○
F01: Parameter Protection function
F01.00
User’s password
00000 - 65535
00000
1
○
F01.01
Menu mode selection
0: Full menu mode
1: Checking menu mode
0
1
○
F01.02
Function codeparameter
initialization (parameter
download)
0: No operation
1: Restore to factory settings
2/3: Keypad stored parameter 1/2
iscopied to control board and update
current function value
4: Clear fault information
0
1
×
F01.03
Copy parameter to keypad
(parameter uploading)
0: No operation
1/2: Current function values are copied
to keypad stored parameter 1/2
0
1
○