Ref. Code
Function Description
Setting Range [Default]
F15.16 = 2
F15.16 = 3
•
SB1: Normally closed stopping button (falling
edge effective)
•
SB2: Normally open forward button (rising edge
effective)
•
SB3: Normally open reverse button (rising edge
effective)
•
K: Direction selection terminals (PMCSx)
•
K = 0 (Forward); K = 1 (Reverse)
•
SB1: Normally closed stopping button (falling
edge effective)
•
SB2: Normally open running button (rising edge
effective)
123
F15.19
DO function selection
0 - 38 [2]
F15.20
Relay function
0 - 31 [31]
0: Reserved.
•
So that the output terminal in a non-functional state, nor make any action.
2: The inverter is running.
•
When the inverter is running, the indicator output.
3: The inverter is running forward.
•
When the inverter is running forward, the output signal output.
4: The inverter is running reversely.
•
When the inverter is running in reverse, the output signal output.
5: DC brake.
•
When the inverter is in DC braking, the output signal output.
9: Frequency level detection signal (FDT).
•
See, for example, F15.31, F15.32.
11: Frequency arrival (FAR).
•
See F15.27 for details.
20: Data output by SCI communication.
•
There is a SCI communication that directly controls the DO or relay output indication signal.
21: Set run time arrive.
•
See F15.36 for details.
23: Set the count value arrive.
•
See F15.37, F15.38 for details.
24: Specifies the count value arrive.
•
See F15.37, F15.38 for details.
FWD
Three-wire
REV
SB2
SB1
SB3
DIx
DIz
DIy
GND
HD09
FWD
Three-wire
FWD
/
REV
SB2
SB1
K
DIx
DIz
DIy
GND
HD09