background image

CAUTION:

Install the Rack Mount Kits as described in this section so that when the switch is installed, the port
side faces the rear of the rack. This configuration optimizes performance in the following ways:

• Provides better airflow by using a plenum. A plenum is an air duct that attaches to the switch

rails, enabling the switch to draw cooler air from outside the rack rather than drawing in heated
air from within the rack.

• Provides room for a gradual bend in the fiber optic cables because the port side of the switch is

set back from the edge of the rack.

Use only the screws provided in the Rack Mount Kit. Using other screws can cause damage to
internal components.

NOTE:

For switches with Port Side Air Intake, install the Rack Mount Kit so that when the switch is installed
the port side faces the front of the rack.

Installation safety guidelines

Verify that the rack and the area around the rack meet the following requirements:

• Plan a rack space that is a 1U high and provides clearance for the switch power cords to run between

the rack sides and the rails at the front of the 19-inch EIA rack.

• Ground all equipment in the rack through a reliable branch circuit connection and maintain ground at

all times. Do not rely on a secondary connection to a branch circuit, such as a power strip.

• Ensure that airflow and temperature requirements are met on an ongoing basis.
• Secure the rack to ensure stability in case of unexpected movement.

Rack mount installation

To install the switch in a rack using the Rack Mount Kit:

Procedure

1.

Place the switch on a flat surface and attach each inner rail to the switch using three flat-head
screws. See 

Figure 17: Attaching the inner rails to the switch

 on page 33.

The rails are labeled Left and Right to designate the left side and right side of the switch as viewed
from its nonport side.

Figure 17: Attaching the inner rails to the switch

2.

Take care to select a mounting location in the rack such that the cutouts in the sides of each rail are
not obstructed. You will route the switch power cords through these holes later in this procedure.

Installing and configuring HPE 16Gb FC switches

33

Summary of Contents for SN3000B

Page 1: ... information on installing configuring and maintaining the HPE StoreFabric SN6500B 16Gb Fibre Channel Switch the HPE SN6000B 16Gb Fibre Channel Switch the HPE SN3000B 16Gb Fibre Channel Switch and the StoreFabric SN4000B SAN Extension Switch It is intended for system administrators and technicians with knowledge of SANs and HPE FC switches ...

Page 2: ...d Enterprise required for possession use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under vendor s standard commercial license Links to third party websites take you outside the Hewlett Packard Enterprise website Hewlett Packard Enterprise has no control ove...

Page 3: ...6Gb FC Switch 16 Overview 16 Platform capabilities 16 Platform components 17 Port side of the switch 18 Nonport side of the switch 18 Software options 19 ISL Trunking 19 Hardware options 20 SFP transceivers 20 HPE StoreFabric SN4000B SAN Extension Switch 20 Overview 20 Platform capabilities 21 Platform components 21 Port side of the switch 22 Nonport side of the switch 22 Software options 22 Hardw...

Page 4: ...onfiguration 50 Backing up the configuration 50 Installing and activating Port Upgrade licenses 50 Fabric OS Native and AG modes 51 Disabling and enabling AG mode 52 Enabling AG mode 52 Disabling AG mode 52 Operating HPE 16Gb FC switches 54 Powering the switch on and off 54 LEDs 54 POST and boot specifications 61 POST 61 Boot 62 Switch maintenance 62 Diagnostic tests 62 Switch management 62 FRU re...

Page 5: ...ations 78 Environmental requirements 80 General specifications 82 Data transmission ranges 84 Memory specifications 87 FC port specifications 87 Serial port specifications 87 AG default port mapping 88 Warranty and regulatory information 90 Warranty information 90 Regulatory information 90 Belarus Kazakhstan Russia marking 90 Turkey RoHS material content declaration 91 Ukraine RoHS material conten...

Page 6: ...o 96 ports in a double 2U height switch only 24 inches deep This small size enables the creation of very dense fabrics in a relatively small space The StoreFabric SN6500B 16Gb FC Switch offers POD licensing Base models of the switch contain 48 ports and up to two additional 24 port POD licenses can be purchased With the appropriate licensing ports can be configured to run at 4 8 or 16 Gb s and opt...

Page 7: ...e licenses to enable these features are not required on this switch Hardware zoning is accomplished at the port level of the switch and by WWN Hardware zoning permits or denies delivery of frames to any destination port address Extensive diagnostic and system monitoring capabilities for enhanced RAS The EZSwitchSetup wizard makes SAN configuration a three step point and click task Real time power ...

Page 8: ... SN6500B StoreFabric 16Gb FC Switch 1 System power LED 2 System status LED 3 USB port 4 FC ports 0 7 5 FC ports 8 47 6 FC ports 48 95 7 Switch ID pull out tab 8 Management Ethernet port with LED 9 Serial console port Figure 1 Port side of the HPE StoreFabric SN6500B 16Gb FC Switch Nonport side of the switch Figure 2 Nonport side of HPE SN6500B StoreFabric 16Gb FC Switch on page 9 shows the nonport...

Page 9: ... or later and do not require a separate license For more information about supported FOS versions see the HPE SPOCK website at http www hpe com storage spock For the latest information on supported software components see the product QuickSpecs available from the Hewlett Packard Enterprise website http www hpe com support sn6500b quickspecs ISL Trunking HPE ISL Trunking is optional software requir...

Page 10: ...12f PremierFlex OM4 MPO MPO Optical Cable 5m 12f PremierFlex OM4 MPO MPO Optical Cable 10m 12f PremierFlex OM4 MPO MPO Optical Cable 15m 12f PremierFlex OM4 MPO MPO Optical Cable 30m 12f PremierFlex OM4 MPO MPO Optical Cable 50m 12f PremierFlex OM4 MPO MPO Optical Cable 100m 12f PremierFlex OM4 MPO MPO Optical Cable HPE PremierFlex MPO to 4xLC OM4 Splitter Cables 5m PremierFlex MPO to 4xLC Optical...

Page 11: ...s 10km FC SFP 1 Pack HPE SN6000B 16Gb FC Switch This section provides an overview of the SN6000B 16Gb FC Switch It describes platform capabilities and components the physical layout of the switch and hardware and software options Overview The SN6000B 16Gb FC Switch is a 48 port autosensing 4 8 10 or 16 Gb s FC switch that delivers the latest Hewlett Packard Enterprise single chip architecture for ...

Page 12: ...fication services In flight data compression and encryption on up to two ports provides efficient link utilization and security VF support improves isolation between VFs FCR service available with the optional Integrated Routing license provides improved scalability and fault isolation FICON FICON Cascading and FICON CUP ready ISL Trunking licensable which allows up to eight ports at 4 8 or 16 Gb ...

Page 13: ...here are two fans per power supply Designed for rack mounting in a 19 inch EIA rack 1U high One LED green amber per FC port to indicate status One LED green for system power One LED green amber for system status Two Ethernet LEDs integrated with RJ 45 for speed and activity status SEEPROM for switch identification Voltage and temperature monitoring RTC with battery Port side of the switch Figure 3...

Page 14: ...eptacle 7 Thumbscrew 8 Handle Figure 4 Nonport side of the HPE SN6000B 16Gb FC Switch Software options The following optional software kits and licenses are available The Power Pack Software Bundle kit includes Adaptive Networking Fabric Watch ISL Trunking Extended Fabric Server Application Optimization Advanced Performance Monitor Fabric Vision Software1 Extended Fabric Fabric Watch Advanced Perf...

Page 15: ... for optimal bandwidth utilization and load balancing For example the FC ports on the SAN Switch are numbered from left to right and color coded in groups of eight to indicate which ports you can combine into trunking groups Figure 5 Trunking groups example on page 15 shows the switch with three trunking groups of eight ports NOTE If your switch is licensed for ISL Trunking use the trunking groups...

Page 16: ...height 1U switch which enables the creation of very dense fabrics in a relatively small space This switch also offers POD licensing Base models of the switch contain 12 ports and an additional 12 port POD license can be purchased NOTE The base model of the SN3000B 16Gb FC Switch includes a single power supply and fan module assembly An optional second power supply and fan module assembly can be ad...

Page 17: ...gement Fabric Watch ISL Trunking and APM Support for AG configuration where server ports connected to the fabric core will be virtualized Hardware zoning is accomplished at the port level of the switch and by WWN Hardware zoning permits or denies delivery of frames to any destination port address Extensive diagnostics and system monitoring capabilities for enhanced RAS Real time power monitoring e...

Page 18: ...t tab 8 FC ports 4 7 NOTE The two LEDs on the serial console port are nonfunctional Nonport side of the switch Figure 7 Nonport side of the HPE SN3000B 16Gb FC Switch on page 18 shows the nonport side of the SN3000B 16Gb Switch 1 2 3 4 5 6 7 Figure 7 Nonport side of the HPE SN3000B 16Gb FC Switch 1 Filler panel Optional Power supply and fan assembly can be added in this slot 2 Power supply and fan...

Page 19: ...k For the latest information on supported software components see the product QuickSpecs available from the Hewlett Packard Enterprise website http www hpe com info sn3000b quickspecs ISL Trunking ISL Trunking is optional software that enables creating trunking groups of ISLs between adjacent switches Up to eight FC ports on the SN3000B 16Gb FC Switch can be used as a trunking group to achieve spe...

Page 20: ...rs Table 4 SFP transceiver options Option Part number 8 Gb Transceivers 8Gb Shortwave B series FC SFP 8Gb LW B series 10km FC SFP B series 8Gb LW 25km FC SFP 16 Gb Transceivers B series 16Gb SFP Short Wave Transceiver 16 Gb Long Wave Transceivers 16Gb Long Wave B series 10km FC SFP 1 Pack HPE StoreFabric SN4000B SAN Extension Switch This section provides an overview of the StoreFabric SN4000B SAN ...

Page 21: ...mitigate the latency effect of a long distance FCIP connection over IP WAN FCIP HCL provides in service firmware upgrade for supporting business operations 24 7 Built in WAN link tester generates traffic over an IP connection to test for maximum throughput congestion loss percentage out of order delivery latency and other network conditions It helps determine the health of a WAN link before deploy...

Page 22: ... FCIP ports QSFP 2 9 1 10 GbE FCIP ports 16 Nonport side of the switch Figure 10 Nonport side of the StoreFabric SN4000B SAN Extension Switch on page 22 shows the nonport side of the StoreFabric SN4000B SAN Extension Switch Figure 10 Nonport side of the StoreFabric SN4000B SAN Extension Switch 1 Fan FRUs 2 Power supply FRUs with integral fans Software options The following optional software kits a...

Page 23: ...ivers Table 5 Transceiver options Option Part number 8 Gb Transceivers 8Gb Shortwave B series FC SFP 1 Pack 8Gb LW B series 10km FC SFP 1 Pack B series 8Gb LW 25km FC SFP 1 Pack 16 Gb Transceivers B series 16Gb SFP Short Wave Transceiver 16 Gb Long Wave Transceivers B series 16Gb SFP LW 10km XCVR B series 16Gb LW 25km FC SFP 1Pk XCVR 1 GbE Transceivers B series 1GbE LX SFP Transceiver B series 1Gb...

Page 24: ...andalone unit One accessory kit with the following items Rack Mount Kit including rails rail mounting hardware and plenum Hewlett Packard Enterprise product documentation including Read Me First Safety Guides User License and Warranty HPE EZ Switch and China ROHS documentation HP SAN Network Advisor DVD Installation and safety considerations You can install the switch in a rack or as a standalone ...

Page 25: ...derations You can organize and manage cables in a number of ways such as using cable channels on the sides of the cabinet or patch panels Before installing the switch consider the following Hewlett Packard Enterprise cabling recommendations Hewlett Packard Enterprise recommends using Hewlett Packard Enterprise PremierFlex cables because they have a minimum bend radius of 2 mm 0 08 inch compared to...

Page 26: ...ble For more information on supported transceivers see SFP transceiver options and the HPE SAN Compatibility Tool at http www hpe com support SANcompatibility Installing the HPE StoreFabric SN6500B 16Gb FC Switch in a rack using the Rack Mount Kit Use the SAN Switch Rack Mount Kit to install your Hewlett Packard Enterprise device in the Hewlett Packard Enterprise custom racks 10000 Series Rack For...

Page 27: ... inch Phillips panhead SEMS screws for use with the StoreFabric SN6500B 16Gb FC Switch This switch requires 10 screws Fourteen 8 32 x 3 16 inch Phillips panhead screws with thread lock do not use Ten 10 32 x 1 2 inch Phillips panhead screws with captive star lock washers Eight 10 alignment washers Eight 10 adapter washers Table Continued Installing and configuring HPE 16Gb FC switches 27 ...

Page 28: ...1 Verify that the required parts and hardware are available See SAN Switch Rack Mount Kit hardware 2 Choose a mounting location for the switch in the rack 3 Attach the rear mounting brackets to the rear rack uprights For a 10000 Series Rack assemble each of the brackets using two 10 32 x 1 2 inch Phillips panhead screws with captive star lock washers and two 10 adapter washers as shown in Figure 1...

Page 29: ...OTE For switches with Port Side Air Intake attach Left outer rail to the right side of the rack and Right outer rail to the left side of the rack a For switches with Port Side Air Intake attach the left outer rail and right outer rail to the rear mounting brackets using two 1 4 20 hex with captive star lock washers attached loosely as shown in Figure 12 Installing the outer rails HPE 10000 Series ...

Page 30: ...holes on the left rail See Figure 13 Assembling the outer rails HPE 10000 Series Rack on page 30 Figure 13 Assembling the outer rails HPE 10000 Series Rack 5 Use the 8 32 x 5 16 inch Phillips panhead SEMS screws in the screw holes marked 16 to attach the two inner rails to the switch For switches with Port Side Air Intake five screws are required for each rail Figure 14 Attaching the inner rails t...

Page 31: ...s to the switch Securing the switch to the outer rails Procedure 1 Insert the switch with the attached inner rails into the outer rails 2 Insert the switch into the rack and install one 10 32 x 1 2 inch Phillips panhead screw with captive star lock washer Repeat for the other side See Figure 15 Securing the switch HPE 10000 Series Rack on page 32 Securing the switch to the outer rails 31 ...

Page 32: ... port 4 5 Ethernet port activity LED 6 Ethernet port speed LED Figure 16 LEDs on port side 5 For switches with Port Side Air Intake proceed to Setting up the switch on page 43 This completes the rack mount procedure Installing the HPE SN6000B 16Gb FC and HPE SN3000B 16Gb FC switches in a rack using the Rack Mount Kit Use the SN6000B and the SN3000B Switch Rack Mount Kits to install the switch in a...

Page 33: ...igh and provides clearance for the switch power cords to run between the rack sides and the rails at the front of the 19 inch EIA rack Ground all equipment in the rack through a reliable branch circuit connection and maintain ground at all times Do not rely on a secondary connection to a branch circuit such as a power strip Ensure that airflow and temperature requirements are met on an ongoing bas...

Page 34: ...on page 34 The rails are labeled Left and Right to designate the left side and right side of the rack as viewed from the front of the cabinet NOTE For switches with Port Side Air Intake attach Left outer rail to the right side of the rack and Right outer rail to the left side of the rack Figure 19 Attaching the outer rails a Slide each rail over the rear mounting brackets b Attach the front of the...

Page 35: ...tening the screws at the rear of the rack Figure 20 Installing the switch in the rack 6 At the front of the rack run the switch power cords from the sides of the rack through the cutouts in the rail and then connect them to the switch power supplies Connect two power cords to the SN6000B 48 port switch Connect one power cord to the SN3000B 24 port switch See Figure 21 Connecting power and installi...

Page 36: ...ply LEDs are amber until the POST is complete and then change to green See Power supply and fan assembly LEDs The switch takes several minutes to boot and complete POST NOTE When installed the plenum covers the power supply switches and LEDs However the LEDs are visible through the air holes in the front of the plenum 9 Slide the plenum over the nonport side of the inner rails taking care to bypas...

Page 37: ...ckard Enterprise recommends that you install the SAN Switch Rack Mount Kit to allow the nonport side of the switch to slide out of the cool air side of the rack In this installation the port side of the switch is set back from the edge of the rack allowing a more gradual bend in the fiber optic cables The following items are required to install the switch in a rack Power cables 2 Phillips screwdri...

Page 38: ...r lock washers Eight 10 alignment washers Eight 10 adapter washers CAUTION For proper airflow the SFP media side of the switch port side must face the rear of the rack This allows cool air to enter the front of the rack and exit from the rear To install the switch in a rack Procedure 1 Verify that the required parts and hardware are available See SAN Switch Rack Mount Kit hardware 2 Choose a mount...

Page 39: ...de of the switch 4 Assemble the outer rails as follows a Attach the left outer rail and right outer rail to the rear mounting brackets using the 10 32 x 1 2 inch Phillips panhead screws with captive star lock washers as shown in Installing the outer rails Four screws are required for attaching the outer rails Figure 25 Installing the outer rails b Install two 10 32 x 1 2 inch Phillips panhead scre...

Page 40: ...e inner rails are attached to the switch Figure 27 Inner rails attachment Securing the switch to the outer rails Procedure 1 Insert the switch with the attached inner rails to the outer rails 2 Insert the switch into the rack and install one 10 32 x 1 2 inch Phillips panhead screw with captive star lock washer Repeat for the other side See Figure 28 Securing the switch on page 41 40 Securing the s...

Page 41: ...eat for the other side See Figure 29 Securing the front of the switch to outer rails on page 41 Figure 29 Securing the front of the switch to outer rails 4 Tighten the screws as mentioned in Installing the outer rails 5 Verify that the switch power and status LEDs on the port side of the switch are green See Figure 30 LEDs on the port side on page 42 Installing and configuring HPE 16Gb FC switches...

Page 42: ... the adhesive side against the chassis place one rubber foot in each indentation and press into place 3 Place the switch on a flat sturdy surface 4 Connect the power cords to each power supply present For the SN6500B SN6000B and SN4000B switches connect the power cords to both power supplies and then to power sources on separate circuits to protect against AC failure For the SN3000B switch connect...

Page 43: ...ic IP addressing you will need the following items not required if using DHCP Fixed IP address IPv4 or IPv6 for the switch Subnet mask value Default gateway value Connecting the serial cable Procedure 1 Connect the serial cable to the serial port on the switch and to an RS 232 serial port on the workstation If the serial port is RJ 45 instead of RS 232 remove the adapter on the end of the serial c...

Page 44: ...g DHCP to set the IP address When using DHCP the switch obtains its IP address subnet mask and default gateway address from the DHCP server The DHCP client can connect only to a DHCP server that is on the same subnet as the switch If your DHCP server is not on the same subnet as the switch use a static IP address Setting a static IP address Procedure 1 Use the ipaddrset command to set the Ethernet...

Page 45: ...trative permissions can set the time zone for the switch by the zone name such as PST by the country and city or by time zone location such as US Central If you do not set the time zone the switch retains the previous zone settings The tstimezone command includes an old option which reverts to the prior time zone format For more information see the Fabric OS Command Reference The tstimezone comman...

Page 46: ... time current in your SAN Hewlett Packard Enterprise recommends that the principal or primary FCS switch time is synchronized with at least one external NTP server The other switches in the fabric automatically take their time from the principal or primary FCS switch All switches in the fabric maintain the current clock server value in nonvolatile memory By default this value is the local clock se...

Page 47: ...ore information on using an NTP server and IPv6 considerations see the Fabric OS Administrator s Guide Configuring the zones and selecting devices See the Fabric OS Administrator s Guide Web Tools Administrator Guide or Network Advisor user manual available from the Storage section of the Hewlett Packard Enterprise website http www hpe com support manuals Connecting devices The Connect Devices win...

Page 48: ... the gold edge down Insert an SFP transceiver into the lower row of ports with the gold edge up a Remove any protector plugs from the SFP transceiver Insert each SFP transceiver right side up in the top row of ports and upside down in the bottom row of ports until it is firmly seated and the latching mechanism clicks The 16 Gb s SFP transceiver does not have a bail Use the pull tab to push the tra...

Page 49: ...ed using the switchstatuspolicyset command The following example shows the default settings of 2 and 0 for DOWN and MARGINAL units for both Bad Power Supplies and Bad Fans switch admin switchstatuspolicyset some output skipped The minimum number of Bad PowerSupplies contributing to DOWN status 0 2 2 Bad PowerSupplies contributing to MARGINAL status 0 2 0 some output skipped Bad Fans contributing t...

Page 50: ...h configuration to the server making it available for downloading to a replacement switch if necessary For instructions on backing up the configuration see the Fabric OS Administrator s Guide 2 Follow the on screen prompts Installing and activating Port Upgrade licenses Procedure 1 Use the portshow command to verify the number of ports licensed on your switch The command output displays Started an...

Page 51: ... When enabling AG mode use the default F_Port to N_Port mappings or change this mapping using the CLI or Web Tools after configuring an IP address as described in Setting the IP address AG simplifies SAN deployment by using NPIV NPIV provides FC switch functions that improve switch scalability manageability and interoperability For a list of F_Ports mapped to N_Ports by default see AG default port...

Page 52: ...ure 1 Before enabling AG mode save the current configuration file using the configupload command 2 Enter the switchshow command to verify the switch mode AG Mode is displayed for switchMode if the switch is in AG mode Native is displayed for switchMode if the switch is in Native mode 3 Enter the switchdisable command to disable the switch The switch must be disabled in order to enable or disable A...

Page 53: ...r disable AG mode 3 Enter the ag modeDisable command to disable AG mode 4 Enter the ag modeshow command to verify that AG mode is disabled switch admin ag modeshow Access Gateway mode is NOT enabled Installing and configuring HPE 16Gb FC switches 53 ...

Page 54: ... do not indicate a healthy state after all boot processes and diagnostic tests are complete Figure 33 LEDs on the port side of the HPE StoreFabric SN6500B 16Gb FC Switch on page 54 Figure 34 LEDs on the port side of the HPE StoreFabric SN4000B SAN Extension Switch on page 55 and Figure 37 Port side of the HPE SN6000B and SN3000B 16Gb FC switches on page 59 show the LEDs on the port side of the swi...

Page 55: ...GbE FCIP port status LED port 1 9 1 10 GbE FCIP port status LED port 4 10 1 10 GbE FCIP port status LED port 8 Figure 34 LEDs on the port side of the HPE StoreFabric SN4000B SAN Extension Switch 1 Power supply DC status LED 2 Power supply AC status LED 3 Fan status LED Figure 35 LEDs on nonport side of the HPE StoreFabric SN6500B 16Gb FC Switch Operating HPE 16Gb FC switches 55 ...

Page 56: ...ly and the power cord is connected to a functioning AC power source Steady green AC input voltage is within the operational range No action is required Power supply DC output status one bicolor LED Flashing amber 1 1 Output voltage is not enabled Verify that the power supply is seated correctly and the captive screw is secured Flashing amber green 2 1 The temperature has exceeded the threshold Ver...

Page 57: ...0B and SN4000B 16Gb FC switches LED name LED color Status of hardware Recommended action System power green No light System is off or there is an internal power supply failure Verify that the system is powered on power supply switches set to I the power cables are attached and the power source is live The unit may be faulty Contact your switch service provider Steady green System is on and power s...

Page 58: ...red Blinking green There is link activity traffic No action is required Ethernet port speed No light Port speed is 10 Mb s No action is required Steady green Port speed is 100 Mb s For the StoreFabric SN6500B 16Gb FC Switch only this indicates a 100 or 1000 Mb s link No action is required FC optical media port status one bicolor LED for each FC port Off There is no light or no signal carrier on th...

Page 59: ...ed 10 GE 40 GE Ethernet port status1 No light The port is offline There is no activity Verify that the power LED is on Check the transceiver and the cable Steady green The port is online and active No action is required 1 This is applicable to the SN4000B SAN Extension Switch only 1 System power LED 2 System status LED 3 Ethernet port activity LED 4 Ethernet port speed LED 5 FC port status LED por...

Page 60: ...action Power supply and fan assembly status No light Power supply fan assembly is not receiving power or is off Verify that the power supply fan assembly is on and seated and the power cord is connected to a functioning power source Steady green Power supply fan assembly is operating normally No action is required Flashing green Power supply fan assembly is faulty When the switch is first powered ...

Page 61: ...stem Initializing hardware Running diagnostic tests on several functions including circuitry port functionality memory statistics counters and serialization To determine whether POST completed successfully Procedure 1 Inspect the switch LEDs to determine whether components are operating properly See LED patterns on the port side of the HPE StoreFabric SN6500B SN6000B SN3000B and SN4000B 16Gb FC sw...

Page 62: ...ented by command through a Telnet session or a console set up to the serial connection to the switch Some tests require that ports be connected by external cables in order to verify the serializer deserializer interface transceiver and cable Some tests require loopback plugs Diagnostic tests run at a link speed of 2 4 8 10 or 16 Gb s FC depending on the speed of the link being tested and the type ...

Page 63: ...tinue to operate during the FRU replacement if you follow the procedures in this chapter However the SN3000B 16Gb FC Switch will continue to operate normally only if it has two power supplies installed The SN3000B 16Gb FC switch comes with only one power supply by default and if removed will have no power Replacing a power supply and fan assembly takes less than two minutes CAUTION Disassembling a...

Page 64: ...sShow command for the StoreFabric SN6500B 16Gb FC Switch Switch admin psshow Power Supply 1 is OK Airflow Direction Portside Intake Forward Power Supply 2 is OK Airflow Direction Portside Intake Forward Switch admin WARNING You must disconnect the power cords from all power sources to completely remove power from the chassis Before beginning the power supply replacement CAUTION Hewlett Packard Ent...

Page 65: ...bly is installed by mistake a critical error message is sent to the console The message will be similar to the following CRITICAL HIL 1611 MISMATCH in PSU FAN Air Flow direction Replace PSU with fan air flows in same direction System will be shut down in 2 minutes Replacing a power supply Replacing a power supply in the StoreFabric SN6500B 16Gb FC Switch or the StoreFabric SN4000B SAN Extension Sw...

Page 66: ... status LED 8 Power cord receptacle Figure 39 HPE StoreFabric SN6500B 16Gb FC Switch power supply 1 AC power socket 2 Handle 3 Integral fan air inlet 4 DC status LED 5 AC status LED 6 Fan air inlet 7 Handle Figure 40 HPE StoreFabric SN4000B SAN Extension Switch power supply 66 Operating HPE 16Gb FC switches ...

Page 67: ...er supply that is being replaced 3 Push the locking tab to the left and hold it there and use the handle on the power supply to pull it straight out and away from the chassis Pull the power supply out slowly to avoid catching a finger on the locking tab 4 Slide the new power supply into the chassis until the locking tab engages CAUTION Do not force the power supply into the chassis If the power su...

Page 68: ...wn in Figure 2 Nonport side of HPE SN6500B StoreFabric 16Gb FC Switch on page 9 and Figure 10 Nonport side of the StoreFabric SN4000B SAN Extension Switch on page 22 The Fabric OS identifies the fan locations from left to right as fan 3 fan 2 and fan 1 CAUTION Disassembling any part of the fan assembly voids the part warranty and regulatory certifications There are no user serviceable parts inside...

Page 69: ... Switch or the HPE StoreFabric SN4000B SAN Extension Switch power supply on page 63 Example of the fanShow command for the StoreFabric SN6500B 16Gb FC switch Switch admin fanshow Fan 1 is Ok speed is 1965 RPM Fan 2 is Ok speed is 2011 RPM Fan 3 is Ok speed is 2011 RPM Fan 4 is Ok speed is 12001 RPM Fan 5 is Ok speed is 11995 RPM Switch admin Replacing an HPE StoreFabric SN6500B 16Gb FC Switch or a...

Page 70: ...le on the fan to pull it straight out and away from the chassis 3 Install the new fan in the chassis a Verify that the airflow direction is the same as that of the fan you are replacing b Orient the new fan with the captive screw on the right as shown in Figure 44 Inserting the fan in the HPE StoreFabric SN6500B 16Gb FC Switch or the HPE StoreFabric SN4000B SAN Extension Switch on page 71 CAUTION ...

Page 71: ... the assemblies from right to left on the nonport side Even though they are contained within a single unit the power supply and fan components are identified separately In the chassisShow command they are identified as Power Supply Unit 1 and Fan Unit 1 The SN6000B switch has two power supply and fan assemblies The two power supply and fan assemblies are hot swappable if replaced one at a time The...

Page 72: ...ing the power supply and fan assembly Procedure 1 If the switch is rack mounted remove the plenum 2 If the switch has two power supply and fan assemblies go to step 3 When replacing the power supply and fan assembly in an SN3000B 16Gb FC Switch that has only one assembly the switch must be powered off before removing the assembly Enter the sysShutDown command before powering off the assembly to ma...

Page 73: ...he AC power switch is in the on position when the switch is installed in the chassis 2 Orient the new power supply and fan assembly with the captive screw on the right as shown in Replacing the power supply and fan assembly CAUTION Do not force the assembly into the chassis If it does not slide in easily ensure that it is oriented correctly before continuing 3 Gently push the power supply and fan ...

Page 74: ... green ensure that the power supply is installed securely and seated properly 7 If the switch is installed in a rack replace the plenum 8 Optional If you are using the CLI enter the psshow command at the command line prompt to display the status Power supply and fan assembly status can also be viewed using Web Tools 74 Operating HPE 16Gb FC switches ...

Page 75: ...cumentation to identify the recommended software update method To download product updates go to either of the following Hewlett Packard Enterprise Support Center Get connected with updates page www hpe com support e updates Software Depot website www hpe com support softwaredepot To view and update your entitlements and to link your contracts and warranties with your profile go to the Hewlett Pac...

Page 76: ...ct your local service provider or go to the CSR website www hpe com support selfrepair Remote support Remote support is available with supported devices as part of your warranty or contractual support agreement It provides intelligent event diagnosis and automatic secure submission of hardware event notifications to Hewlett Packard Enterprise which will initiate a fast and accurate resolution base...

Page 77: ... physical specifications Dimension Value Height 1U or 4 3 cm 1 7 in Depth without plenum 44 3 cm 17 4 in Width The slightly increased width requires a slim rail rack mount kit for mounting 43 8 cm 17 2 in Weight with two power supply and fan assemblies and no SFPs installed 9 2 kg 20 2 lb Weight with one power supply and fan assembly and no SFPs installed 7 82 kg 17 25 lb Table 14 StoreFabric SN40...

Page 78: ...circuit connection Plenum installed to prevent overheating Additional weight of switch not to exceed the cabinet s weight limits Cabinet secured to ensure stability in case of unexpected movement Power supply specifications The power supplies are universal and operate worldwide without voltage jumpers or switches They meet IEC 61000 4 5 surge voltage requirements and support autoranging to accommo...

Page 79: ...er supply output 150 W at 12 VDC Maximum current 12 5 A at 12 VDC Input line protection Both AC lines are fused System power consumption 110 W with all 48 ports populated with 16 Gb s SWL optical media 72 W with empty chassis and no optical media Table 18 SN3000B 16Gb FC Switch power supply specifications Specification Values Input voltage Range 85 264 VAC nominal 100 240 VAC Input frequency Range...

Page 80: ... for both operating and nonoperating such as during transportation or storage conditions Table 20 HPE StoreFabric SN6500B 16Gb FC Switch environmental requirements Condition Acceptable range during operation Acceptable range during nonoperation Ambient temperature 0º to 40ºC 32º to 104ºF 25º to 70ºC 13º to 158ºF Humidity 10 to 85 RH noncondensing at 40ºC 104ºF 10 to 90 RH noncondensing at 70ºC 158...

Page 81: ... cubic ft m Nominal 59 47 cubic m h 35 cubic f m N A Heat dissipation 338 BTU hr 32 port configuration 375 BTU hr 48 port configuration N A Table 22 StoreFabric SN4000B SAN Extension Switch environmental requirements Condition Acceptable range during operation Acceptable range during nonoperation Ambient temperature 0º to 40ºC 32º to 104ºF 25º to 70ºC 13º to 158ºF Humidity 5 to 93 RH noncondensing...

Page 82: ...s Switch latency 2 100 ns 2 1 microseconds with no Forward Error Correction Table 24 SN6000B 16Gb FC Switch general specifications Specification Description Configurable port types F_Port E_Port M_Port EX_Port and D_Port System architecture Nonblocking shared memory switch System processor PowerPC 440EPx at 667 MHz ANSI FC protocol FC PH Modes of operation FC Class 2 and Class 3 Fabric initializat...

Page 83: ...s 3 and Class F frames for the 24 port chassis Table 26 StoreFabric SN4000B SAN Extension Switch general specifications Specification Description Configurable port types F_Port E_Port M_Port D_Port and Ex_Port System architecture Nonblocking shared memory extension switch System processors Quadcore P3041 Freescale PowerPC processor 1 5 GHz Cavium 6880 for frame packet processing Blitzer for Encryp...

Page 84: ... 150 m 492 ft 150 m 492 ft N A 10 Gb s 33 m 108 ft 82 m 269 ft 300 m 984 ft 550 m 1 804 ft N A 16 Gb s 15 m 49 ft 35 m 115 ft 100 m 328 ft 125 m 410 ft N A LWL 4 Gb s N A N A N A N A 30 km 18 6 mi 8 Gb s N A N A N A N A 10 km 6 2 mi 40 km 24 8 mi 10 Gb s N A N A N A N A 10 km 6 2 mi 16 Gb s N A N A N A N A 10 km 6 2 mi ELWL 16 Gb s N A N A N A N A 25 km 15 5 mi 1 Hewlett Packard Enterprise does no...

Page 85: ...m 984 ft 550 m 1 804 ft N A 16 Gb s 15 m 49 ft 35 m 115 ft 100 m 328 ft 125 m 410 ft N A LWL 8 Gb s N A N A N A N A 10 km 6 2 mi 10 Gb s N A N A N A N A 10 km 6 2 mi 16 Gb s N A N A N A N A 10 km 6 2 mi ELWL 4 Gb s N A N A N A N A 30 km 18 6 mi 8 Gb s N A N A N A N A 25 km 15 5 mi Table 29 StoreFabric SN4000B SAN Extension Switch supported optics speeds cables and distances SFP Speed Cable size mi...

Page 86: ...P 16G ELWL 25km SFP 10G FC SWL SFP 10G FC LWL 10km SFP 8G SWL SFP 8G LWL 10km SFP 8G ELWL 25km SFP SmartOptics 16G DWDM 40km SFP not in CSD 3rd party reference sell SmartOptics 8G DWDM 40km SFP not in CSD 3rd party reference sell SmartOptics 8G CWDM 70km SFP not in CSD 3rd party reference sell For Ethernet user data ports the following SFP SFP fiber optic and copper transceivers are supported 1 10...

Page 87: ... 16 Gb s depending on SFP models and are able to autonegotiate to the maximum link speed NOTE Hewlett Packard Enterprise does not support 2 Gb s connectivity to the StoreFabric SN6500B 16Gb FC Switch SN6000B 16Gb FC Switch SN3000B 16Gb FC Switch or StoreFabric SN4000B SAN Extension Switch Serial port specifications The serial port is located on the port side of the switch and uses an RJ 45 connect...

Page 88: ...ed N A AG default port mapping SN6000B 16Gb FC Switch AG default port mapping lists the port mappings of F_Ports to N_Ports Table 33 SN6000B 16Gb FC Switch AG default port mapping Total ports F_Ports N_Ports Default port mapping 48 0 39 40 47 0 4 mapped to 40 5 9 mapped to 41 10 14 mapped to 42 15 19 mapped to 43 20 24 mapped to 44 25 29 mapped to 45 30 34 mapped to 46 35 39 mapped to 47 88 AG def...

Page 89: ...ault port mapping Total ports F_Ports N_Ports Default port mapping 24 0 15 16 23 0 1 mapped to 16 2 3 mapped to 17 4 5 mapped to 18 6 7 mapped to 19 8 9 mapped to 20 10 11 mapped to 21 12 13 mapped to 22 14 15 mapped to 23 Specifications 89 ...

Page 90: ...t ProLiantServers Warranties HPE Enterprise Servers www hpe com support EnterpriseServers Warranties HPE Storage Products www hpe com support Storage Warranties HPE Networking Products www hpe com support Networking Warranties Regulatory information Belarus Kazakhstan Russia marking Manufacturer and Local Representative Information Manufacturer information Hewlett Packard Enterprise Company 3000 H...

Page 91: ...ing from within each new decade with 2000 as the starting point for example 238 2 for 2002 and 38 for the week of September 9 In addition 2010 is indicated by 0 2011 by 1 2012 by 2 2013 by 3 and so forth YYWW where YY indicates the year using a base year of 2000 for example 0238 02 for 2002 and 38 for the week of September 9 Turkey RoHS material content declaration Ukraine RoHS material content de...

Page 92: ...ve component or assembly Grounding methods There are several methods for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance in the ground cords To provide proper ground ...

Page 93: ...anced Performance Monitoring ARL Adaptive Rate Limiting CUP Control Unit Port D_Port Diagnostic port DDR2 Double data rate 2 DHCP Dynamic Host Configuration Protocol DPOD Dynamic Ports on Demand DPS Dynamic Path Selection DWDM Dense wavelength division multiplexing ECC Error correcting code ELWL Extended Long Wavelength FC Fibre Channel FCIP Fibre Channel over Internet Protocol Glossary 93 ...

Page 94: ...RU Field replaceable unit FTP File Transfer Protocol GMT Greenwich Mean Time HBA Host Bus Adapter HCL Hot Code Load IOPS Input and Output Operations Per Second ISL Inter Switch Link LC Lucent connector LTU License To Use LWL Long Wavelength M_Port Mirror port NPIV N_Port ID Virtualization NTP Network Time Protocol server OM3 Optical Multimode 3 94 Glossary ...

Page 95: ...t Computer RTC Real time Clock SAN Storage Area Network SCP Secure Copy SDRAM Synchronous Dynamic Random Access Memory SEEPROM Serial Electrically Erasable Programmable Read Only Memory SFP Small Form Factor Pluggable SNMP Simple Network Management Protocol SWL Short Wavelength UTC Coordinated Universal Time VF Virtual Fabric WWN World Wide Name Glossary 95 ...

Reviews: