Installation
53
User Manual
2.9
FRU Replacements
2.9.1 Power Supply
The systems that are equipped with two replaceable power supply units work in a redundant con-
figuration. Either unit may be extracted without bringing down the system.
To extract a power supply unit:
Step 1.
Remove the power cord from the power supply unit.
Step 2.
Grasping the handle with your hand, push the latch release with your thumb while pulling
the handle outward. As the power supply unit unseats, the power supply unit status LEDs
will turn off.
Step 3.
Remove the power supply unit.
The following information does not apply to the SN2100M/SN2010M series. The
SN2100M/SN2010M systems include two non-replaceable power supply units and
four non-replaceable fan units.
Make sure that the power supply unit that you are NOT replacing is showing all green,
for both the power supply unit and System Status LEDs.
Power supply units have directional air flows similar to the fan module. The fan mod-
ule airflow must coincide with the airflow of all of the power supply units. If the power
supply unit airflow direction is different from the fan module airflow direction, the
system
’s
internal temperature will be affected.
For power supply unit air flow direction, refer to
The power supply slots of SN2410M/SN2410bM should not be left empty for more
than 5 minutes.