Installation
51
User Manual
Step 5.
Before attempting a remote (for example, SSH) connection to the system, check the mgmt0
interface configuration. Specifically, verify the existence of an IP address. To check the cur-
rent mgmt0 configuration, enter the following command:
Step 6.
Check the software version embedded in your system, using the command ‘show version’.
Compare this version to the latest version that can be retrieved from HPE support site. To
upgrade software, please refer to the MLNX-OS User Manual.
r-qa-sit-switch01 (config) # show interfaces mgmt0
Interface mgmt0 status:
Comment:
Admin up: yes
Link up: yes
DHCP running: yes
IP address: 192.168.1.100
Netmask: 255.255.255.0
IPv6 enabled: yes
Autoconf enabled: no
Autoconf route: yes
Autoconf privacy: no
DHCPv6 running: no
IPv6 addresses: 1
IPv6 address: fe80::202:c9ff:fe63:b55a/64
Speed: 1000Mb/s (auto)
Duplex: full (auto)
Interface type: ethernet
Interface source: physical
MTU: 1500
HW address: 00:02:C9:63:B5:5A
RX bytes: 968810197 TX bytes: 1172590194
RX packets: 10982099 TX packets: 10921755
RX mcast packets: 0 TX discards: 0
RX discards: 0 TX errors: 0
RX errors: 0 TX overruns: 0
RX overruns: 0 TX carrier: 0
RX frame: 0 TX collisions: 0
TX queue len: 1000