72
User Manual
5
Troubleshooting
5.1
Troubleshooting Instructions
Table 24 - Troubleshooting
Problem Indicator
Symptoms
Cause and Solution
LEDs
System Status LED is
blinking for more than
5 minutes
Cause:
MLNX-OS software did not boot properly and only
firmware is running.
Solution: Connect to the system via the console port,
and check the software status. You might need to con-
tact an FAE if the MLNX-OS software did not load
properly
System Status LED is
red
Cause:
• Critical system fault (CPU error, bad firmware)
• Over Temperature
Solution:
• Check environmental conditions (room tempera-
ture)
Fan Status LED is red
Cause:
Possible fan issue
Solution:
• Check that the FAN is fully inserted and nothing
blocks the airflow
• Replace the FAN FRU if needed (possible in
SN2700M and SN2410M/SN2410bM only)
PSU Status LED is red
Cause:
Possible PSU issue
Solution:.
• Check/replace the power cable
• Replace the PSU if needed (possible in SN2700M
and SN2410M/SN2410bM only)