Processors
The following limitations are for the Intel Xeon Gold 6244 (G6244) processor:
• The processor does not support enhanced processor performance
• LFF drives with drive capacities greater than or equal to 10 TB are not supported for the Apollo
DX2200 Gen10 Chassis series with three drives per node.
Description
Chassis
Fan configuration Number of drives
supported by the
server
Maximum inlet
ambient
temperature
Processor with a
TDP of 135 W or
more, except
G6244
Apollo DX2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
5 to 6 drives
25°C (77°F)
5 to 6 drives
Not supported
0 to 4 drives
30°C (86°F)
Apollo DX2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
30°C (86°F)
Apollo DX2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
30°C (86°F)
Apollo DX2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
30°C (86°F)
Intel Xeon Gold
6244 (G6244)
processor
Apollo DX2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
5 to 6 drives
Not supported
5 to 6 drives
Not supported
0 to 4 drives
Not supported
Apollo DX2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
Not supported
Table Continued
96
Specifications
Summary of Contents for ProLiant DX190r Gen10
Page 21: ...Customer self repair 21...
Page 22: ...22 Customer self repair...
Page 23: ...Customer self repair 23...