Description
Chassis
Fan configuration Number of drives
supported by the server
Maximum inlet
ambient
temperature
(12 LFF
backplane)
5 to 6 drives
Not supported
0 to 4 drives
35°C (95°F)
Apollo DX2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
30°C (86°F)
Apollo DX2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
30°C (86°F)
Apollo DX2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
Not supported
E208e-p
controller
Apollo DX2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
5 to 6 drives
25°C (77°F)
5 to 6 drives
Not supported
0 to 4 drives
30°C (86°F)
Apollo DX2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
28°C (82.4°F)
Apollo DX2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
28°C (82.4°F)
Apollo DX2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
28°C (82.4°F)
When the P824i-p controller is installed, the components installed in the Apollo DX2600 Gen10 Chassis chassis will
support up to 12 drives
The energy pack is supported only with Smart Array type-p controllers. Due to thermal concerns, it is recommended
to remove the energy pack if these controller types are not installed in the chassis.
The drive capacity must be less than 10 TB.
100