Cabling
HPE ProLiant Gen10 DL Servers Storage Cabling Guidelines
When installing cables, observe the following:
• All ports are labeled:
◦ System board ports
◦ Controller ports
◦ 12G SAS Expander ports
• Most data cables have labels near each connector with destination port information.
• Some data cables are pre-bent. Do not unbend or manipulate the cables.
• Before connecting a cable to a port, lay the cable in place to verify the length of the cable.
• When routing cables from the front to the rear of the server, use the cable channels on either side of the
chassis.
Cable matrix
Use the following tables to find cabling information and part numbers.
SAS/SATA kits
Option kit
Cable part
number*
From
To
Power cable part
number
2SFF SAS/SATA drive cage
869952-001
1
Drive
backplane
System board 870479-001
2
8SFF SAS/SATA drive cage
870480-001
3
Drive
backplane
(drive boxes 1,
3, 4, and 6)
Primary riser
cage
Tertiary riser
cage
870479-001
2
8SFF SAS/SATA drive cage
870483-001
3
Drive
backplane
(drive boxes
1–6)
Primary riser
cage
Tertiary riser
cage
870479-001
2
8SFF SAS/SATA drive cage (mini
SAS)
870492-001
4
Drive
backplane
(drive boxes 1,
3, 4, and 6)
Primary riser
cage
Tertiary riser
cage
870479-001
2
Table Continued
118