407
virtual chassis, the command applies to all member devices. If you do not specify a card, the
command applies to all cards of the specified member device. (In IRF mode.)
test
test-name
: Specifies a test by its name, a case-insensitive string of 1 to 31 characters. If you do
not specify this option, the command applies to all diagnostic tests on the specified card.
Usage guidelines
This command does not clear the next execution time in detailed test results.
Examples
# (In standalone mode.) Clear test results for test
HGMonitor
on card 1.
<Sysname> reset diagnostic result slot 1 test HGMonitor
# (In IRF mode.) Clear test results for test
HGMonitor
on card 1 of IRF member device 1.
<Sysname> reset diagnostic result chassis 1 slot 1 test HGMonitor
Related commands
display diagnostic result