382
Destination
Source
modules
Common
log
Security log
Diagnostic
log
Hidden log
modules
Monitor
terminal
All supported
modules
debugging Disabled
Disabled
Disabled
Log host
All supported
modules
informational Disabled
Disabled
informational
Log buffer
All supported
modules
informational Disabled
Disabled
informational
Log file
All supported
modules
informational Disabled
Disabled
informational
Security log
file
All supported
modules,
cannot be
filtered
Disabled
Debugging, which
cannot be filtered
Disabled Disabled
Diagnostic
log file
All supported
modules,
cannot be
filtered
Disabled Disabled
Debugging,
which cannot be
filtered
Disabled
Views
System view
Predefined user roles
network-admin
mdc-admin
Parameters
module
-
name
: Specifies a module by its name. For instance, to output FTP information, set this
argument to FTP. You can use the
info-center source ?
command to view the modules supported
by the device.
default
: Specifies all modules, which can be displayed by using the
info-center source ?
command.
console
: Outputs logs to the console.
logbuffer
: Outputs logs to the log buffer.
logfile
: Outputs logs to the log file.
loghost
: Outputs logs to the log host.
monitor
: Outputs logs to the monitor terminal.
deny
: Disables log output.
level
severity
: Specifies a severity level in the range of 0 to 7. The smaller the severity value, the
higher the severity level. See
for more information. Logs at the specified severity level and
higher levels are allowed or denied to be output.
Usage guidelines
If you do not set an output rule for a module, the module uses the default output rule or the output
rule set by using the
default
keyword.
If you use the command multiple times, only the most recent output rule takes effect for the specified
module.