75
Parameters
interval
: Specifies the interval in minutes, in the range of 1 to 35791394.
Usage guidelines
NQA forms statistics within the same collection interval as a statistics group. To display information
about the statistics groups, use the
display nqa statistics
command.
Examples
# Configure the system to collect the ICMP echo operation statistics at 2-minute intervals.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] statistics interval 2
statistics max-group
Use
statistics max-group
to configure the maximum number of statistics groups that can be saved.
Use
undo statistics max-group
to restore the default.
Syntax
statistics max-group
number
undo statistics max-group
Default
A maximum of two statistics groups can be saved.
Views
DHCP/DLSw/DNS/FTP/HTTP/SNMP/TCP/voice operation view
ICMP/UDP echo operation view
Path/UDP jitter operation view
Predefined user roles
network-admin
mdc-admin
Parameters
number
: Specifies the maximum number of statistics groups, in the range of 0 to 100. To disable
statistics collection, set the value to 0.
Usage guidelines
When the maximum number of statistics groups is reached and a new statistics group is to be saved,
the earliest statistics group is deleted.
Examples
# Configure the NQA to save up to five statistics groups for the ICMP operation.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] statistics max-group 5