NOTE:
Configurations other than those listed in
Removing and replacing a hot-swap power supply
not have 1+1 power redundancy and are not supported.
Power redundancy is dependent on the number of power supplies, processors, and DIMMs in a
system. Additional components, such as HDDs or PCIe cards, do not impact power redundancy.
The server also supports power capping. Power capping operation can be observed through iLO 3. For
more information, see the
HPE Integrity iLO 3 Operations Guide
.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the power supply or power supply
blank to cool before touching it.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all bays are
populated with either a component or a blank.
To remove the component:
Procedure
1.
Determine how many hot-swap power supplies are installed:
a.
If only one hot-swap power supply is installed, power off and remove the power cord from the
server (
b.
If more than one hot-swap power supply is installed, continue with the next step.
2.
Access the product rear panel (
3.
Disconnect the power cord from the power supply.
4.
Remove the hot-swap power supply.
WARNING:
To reduce the risk of electric shock or damage to the equipment, do not connect the power cord
to the power supply until the power supply is installed.
Removal and replacement procedures
147