3–16
hp workstation xw4100 service and technical reference guide
system management
The following table lists the various keyboard light combinations used by the Boot Block ROM,
as well as the meaning and action associated with each combination.
3.2.4 remote security management
Remote Security Management allows the system administrator to safely set or modify security
features on remote workstations directly from the centralized network management console.
Enabling the system administrator to perform these tasks remotely, on multiple workstations,
results in consistent deployment of and greater control over client workstation security
parameters over the network.
NOTE:
Your workstation must be powered on, or turned on through Remote Wakeup, to take
advantage of Remote Security Management. Use of Remote Security Management also requires
an established setup password.
For more information about the Remote Management Setup software and enabling Remote
Security Management, refer to the online Remote Management Administrators Guide. The
Remote Management Administrators Guide is included with the Remote Management Setup
Utilities, and is available on the HP Web site at
www.hp.com.
remote wakeup and remote shutdown
If your workstation has a network card installed, it may support the Remote Wakeup and Remote
Shutdown functions. These functions allow a system administrator to power on and power off a
client workstation from a remote location supported by PC LAN management tools.
NOTE:
Third-party software tools are required to remotely distribute software.
keyboard light combinations used by Boot Block ROM
failsafe
boot block
mode
keyboard
LED color
keyboard LED
activity
state/message
Num Lock
Green
On
ROMPaq diskette not present, is bad,
or drive not ready.*
Caps Lock
Green
On
Enter password.*
Num, Caps,
Scroll Lock
Green
Turn on and off
2 times (accompanied
by 1 long and 3 short
beeps)
ROM flash failed.*
Num, Caps,
Scroll Lock
Green
On
Boot Block ROM Flash successful.
Turn power off, then on to reboot.
NOTE:
Diagnostic lights do not flash on USB keyboards.
*Insert valid ROMPaq diskette in drive A. Turn power switch off, then on to reflash ROM. If ROM
flash is successful, all three keyboard LEDs will light up, and you will hear a rising tone series of
beeps. Remove diskette and turn power off, then on to restart the workstation.
Summary of Contents for Workstation xw4100
Page 146: ...C 4 hp workstation xw4100 service and technical reference guide SATA Devices ...
Page 158: ...E 8 hp workstation xw4100 service and technical reference guide connector pin assignments ...
Page 160: ...F 2 hp workstation xw4100 service and technical reference guide power cord set requirements ...
Page 194: ...index 8 hp workstation xw4100 service and technical reference guide index ...