1. 6 mm M3 mounting screws
2. 6 mm M3 offset mounting screws
Figure 6 Attaching locating screws in a typical HP ProLiant 350 or 370
Other servers
Attach the appropriate mounting hardware. Refer to the manufacturer’s documentation for instructions.
•
If you are installing on a server that requires a tray, place the tape drive in the tray.
•
Some servers have snap-on mounting rails attached to the
fi
ller panel. These can be removed
and attached to the tape drive with screws.
Install drive - all servers
NOTE:
If cable access for the tape drive bay is awkward, it may be easier to access power and other connections
if the tape drive is installed in the top bay. You may need to move other devices to lower bays to achieve
this. Refer also to your server documentation.
Slide the tape drive into the open bay, aligning the tray or rails with the slots in the bay, as shown in
Figure 7
on page 26.
Ultrium half-height SAS Tape Drives
25
Summary of Contents for StorageWorks Ultrium 448
Page 12: ...12 About this guide ...
Page 36: ...36 Installing an internal Ultrium tape drive ...
Page 48: ...48 Installing an external Ultrium tape drive by connecting to an internal SAS port ...
Page 52: ...52 Installing an external Ultrium tape drive by connecting to an external SAS port ...
Page 54: ...54 Verify installation ...
Page 58: ...58 Operating your tape drive ...
Page 68: ...68 Using HP OBDR ...
Page 72: ...72 Diagnostic Tools and Performance ...
Page 80: ...80 Replacing a tape drive ...