CXO7373A
2
3
1
1. EMU alphanumeric display
2. Function select
3. Display group select
Figure 21 EMU alphanumeric display and controls
c.
Verify the state of the following status indicators (
Figure 22
).
• Both power supply status indicators are on.
• The EMU heartbeat is
fl
ashing.
• The EMU enclosure power LED is on.
• Both I/O module power status indicators are on.
• All four I/O module port status indicators are off.
25204a
Figure 22 Enclosure operational status indicators
Connecting the cables
Figure 23
shows a FC-AL con
fi
guration with the maximum allowed DS2500s.
To connect
fi
bre optic cables on a direct connect model:
1.
Remove the dust covers from the I/O module ports.
2.
Insert an SFP in each I/O port.
3.
Attach one end of an FC cable to I/O module A—port 2 SFP, and the other end of the cable to either:
• The SFP in port 1 of I/O module A on the preceding enclosure if you are adding the DS2500 to
an existing storage system, or
• The HBA if the DS2500 is the
fi
rst or only enclosure.
4.
Attach one end of an FC cable to the SFP in port 1 on I/O module A and the other end of the
cable to either:
HP StorageWorks 2500 Disk System user guide
33