Table 29 Voltage and current sensor locations
Element number (en.)
Location
01.
Power supply 1, +5 VDC
02.
Power supply 1, +12 VDC
03.
Power supply 2, +5 VDC
04.
Power supply 2, +12 VDC
Table 30 Voltage and current threshold error conditions
Error
condition
Severity
Description
Actions
1.2.
en
.01
Noncritical
Location
en
is approaching the critical
threshold for high voltage.
1.2.
en
.02
Critical
Location
en
has reached the critical
threshold for high voltage.
1.2.
en
.03
Noncritical
Location
en
is approaching the critical
threshold for low voltage.
1.2.
en
.04
Critical
Location
en
has reached the critical
threshold for low voltage.
1.3.
en
.01
Noncritical
Location
en
is approaching the critical
threshold for high current.
1.3.
en
.02
Critical
Location
en
has reached the critical
threshold for high current.
Contact your HP-authorized
service representative.
Backplane error conditions
The format of a backplane error condition report is
8.2.01.ec
, where:
•
8.2.
identi
fi
es a backplane error.
•
01.
is the two-character backplane element number.
•
ec
is the error code.
Table 31 Backplane error conditions
Error
condition
Severity
Description
Actions
8.2.01.10
Noncritical
Invalid backplane NVRAM read.
The EMU begins an automatic recovery
process.
If the automatic recovery does
not correct the problem, contact
your HP-authorized service
representative.
8.2.01.11
Noncritical
Backplane NVRAM write error
8.2.01.12
Noncritical
Backplane NVRAM read error
8.2.01.13
Noncritical
Backplane WWN read error
Contact your HP-authorized service
representative.
I/O module error conditions
The format of an I/O module error condition report is
8.7.en.ec
, where:
•
8.7.
identi
fi
es an I/O module error.
•
en.
identi
fi
es which I/O module is affected.
86
EMU-generated error condition reports
Summary of Contents for StorageWorks 2500
Page 1: ...HP StorageWorks 2500 Disk System user guide Part number 5697 6800 Second edition June 2007 ...
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 44: ...44 Using the EMU ...
Page 54: ...54 Troubleshooting ...
Page 64: ...Figure 35 Replacing a disk drive 64 Customer self repair ...
Page 68: ...68 Specifications ...
Page 78: ...78 Regulatory notices ...