HP ProLiant DL140 Server Setup and Installation Guide
56
E
Server Specifications
Operating and Performance Specifications
Table E-1: Operating and Performance Specifications
Dimensions/Feature
Height
4.37 cm
(1.72 in)
Depth
60.22 cm
(23.7 in)
Width
43.0 cm
(16.9 in)
Weight (maximum)
11.00kg
(24.2 lb)
Input requirements
Rated input voltage
100 VAC to 240 VAC
—
Rated input frequency
50 Hz to 60 Hz
—
Rated input current
4.5A (100-120 V) / 2.5A (200-240 V)
Rated input power
440 W
—
BTUs per hour
1509
—
Power supply output
Rated steady-state power
325 W
—
Maximum peak power
422 W (for max. duration of 15
seconds)
—
Temperature range
1
Operating (See note)
10
°
C to 35
°
C
(50
°
F to 95
°
F)
Shipping (See note)
-40
°
C to 60
°
C
(-40
°
F to 140
°
F)
Relative humidity (noncondensing)
2
Operating (See note)
10% to 90%
—
Non-operating (See note)
10% to 95%
—
Maximum wet bulb temperature
28
°
C
(82.4
°
F)
1
Operating temperature has an altitude derating of 1
°
C per 308.4 M (1.8
°
F per 1000 ft). No
direct sunlight.
2
Storage maximum humidity of 95 percent based on maximum temperature of 45
°
C
(113
°
F). Altitude minimum for storage is 70 KPa..
All manuals and user guides at all-guides.com