Specifications 84
Specifications
Environmental specifications
Specification
Value
Temperature range*
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Non-operating
-30
°
C to 60
°
C (-22
°
F to 140
°
F)
Relative humidity
(non-condensing)
Operating, maximum wet bulb
temperature of 28°C (82.4°F)
10% to 90%
Non-operating, maximum wet
bulb temperature of 38.7°C
(101.7°F)
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
Server specifications
Specification
Tower model
Rack model
Height
36.82 cm (14.50 in)
17.50 cm (6.89 in)
Depth
47.52 cm (18.71 in)
47.52 cm (18.71 in)
Width
17.50 cm (6.89 in)
36.82 cm (14.50 in)
Weight, minimum for SFF drive cage
11.00 kg (24.22 lb)
11.00 kg (24.22 lb)
Weight, maximum for SFF drive cage
17.00 kg (37.44 lb)
17.00 kg (37.44 lb)
Weight, minimum for LFF drive cage
11.90 kg (26.21 lb)
11.90 kg (26.21 lb)
Weight, maximum for LFF drive cage
19.00 kg (41.85 lb)
19.00 kg (41.85 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HP 350 W 4U Integrated Power Supply
•
HP 460 W CS Gold Hot-plug Power Supply (92% efficiency)
CAUTION: