42
HP ProLiant DL580 Generation 3 Server Maintenance and Service Guide
Warning: The serial number should ONLY be modified by
qualified service personnel. This value should always
match the serial number located on the chassis.
4.
Press the Enter key to clear the warning.
5.
Enter the serial number.
6.
Select Product ID. The following warning is displayed.
Warning: The Product ID should ONLY be modified by
qualified service personnel. This value should always
match the Product ID located on the chassis.
7.
Enter the product ID and press the Enter key.
8.
Press the Escape key to close the menu.
9.
Press the Escape key to exit RBSU.
10.
Press the F10 key to confirm exiting RBSU. The server will automatically
reboot.
Removing the system battery
If the server no longer automatically displays the correct date and time, you
might need to replace the battery that provides power to the real-time clock.
Under normal use, battery life is five to 10 years.
WARNING: The computer contains an internal lithium
manganese dioxide, a vanadium pentoxide, or an alkaline battery
pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
•
Do not attempt to recharge the battery.
•
Do not expose the battery to temperatures higher than
60°C (140°F).
•
Do not disassemble, crush, puncture, short external contacts,
or dispose of in fire or water.
•
Replace only with the spare designated for this product.
1.
Power down the server ("Powering down the server" on page
18
).
2.
Extend or remove the server from the rack ("Removing the server from the
rack" on page
19
).