Component identification 15
•
8+8-bay SFF drive model
Drive LED definitions
Item LED
Status
Definition
1
Locate
Solid blue
The drive is being identified by a host application.
Flashing blue
The drive carrier firmware is being updated or requires an update.
2
Activity ring
Rotating green
Drive activity
Off
No drive activity
3
Do not remove
Solid white
Do not remove the drive. Removing the drive causes one or more of
the logical drives to fail.
Off
Removing the drive does not cause a logical drive to fail.
4
Drive status
Solid green
The drive is a member of one or more logical drives.
Flashing green
The drive is rebuilding or performing a RAID migration, stripe size
migration, capacity expansion, or logical drive extension, or is
erasing.
Flashing
amber/green
The drive is a member of one or more logical drives and predicts
the drive will fail.
Flashing amber The drive is not configured and predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID controller.
IMPORTANT:
When the SAS-enabled riser board with the Smart Array B320i Controller is
installed in the server, the embedded Smart Array B120i Controller is disabled automatically.
When this condition occurs:
•
Drives connected to the system board operate in AHCI or Legacy mode.
•
In AHCI or Legacy mode, drives cannot be a part of a hardware RAID or a logical drive.
•
The Locate, Drive status, and Do not remove LEDs of the affected drives are disabled.
Summary of Contents for ProLiant DL388e
Page 82: ...Cabling 82 Cabling Storage cabling 4 drive LFF SATA cabling Mini SAS cable Power cable ...
Page 83: ...Cabling 83 4 drive SFF SATA cabling Mini SAS cable Power cable ...
Page 84: ...Cabling 84 6 drive LFF SATA cabling Mini SAS cable 1 and two port SATA cable 2 Power cable ...
Page 97: ...Cabling 97 o Secondary GPU power cabling ...
Page 131: ...Support and other resources 131 ...
Page 132: ...Support and other resources 132 ...