Component identification 9
Front panel LEDs and buttons
Item Description
Status
1
Internal health LED
Green = Normal
Amber = System degraded. Refer to system board LEDs to identify
component in degraded state.
Red = System critical. Refer to system board LEDs to identify
component in critical state.
2
External health LED
(power supply)
Green = Normal
Amber = Power redundancy failure
Red = Critical power supply failure
3
NIC 1 link/activity LED
Green = Network link
Flashing = Network link and activity
Off = No link to network. If power is off, view the rear panel
RJ-45 LEDs for status.
4
NIC 2 link/activity LED
Green = Network link
Flashing = Network link and activity
Off = No link to network. If power is off, view the rear panel
RJ-45 LEDs for status.
5
UID LED button
Blue = Activated
Flashing = System being remotely managed
Off = Deactivated
6
Power On/Standby
button/system power LED
Green = System on
Amber = System shut down, but power still applied
Off = Power cord not attached or power supply failure