Maximum rated input power
580 W at 100 VAC
560 W at 200 VAC
576 W at 240 VDC for China
only
BTUs per hour
1979 at 100 VAC
1911 at 200 VAC
1965 at 240 VDC for China
only
Power supply output
Rated steady-state power
500 W at 100 VAC to 127 VAC
input
500 W at 200 VAC to 240 VAC
input
500 W at 240 VDC input for
China only
Maximum peak power
500 W at 100 VAC to 127 VAC
input
500 W at 200 VAC to 240 VAC
input
500 W at 240 VDC input for
China only
HPE 800W Flex Slot Platinum Hot-plug Power Supply
Specification
Value
Input requirements
Rated input voltage
100 to 127 VAC
200 to 240 VAC
240 VDC for China only
Rated input frequency
50 Hz to 60 Hz
Not applicable to 240VDC
Rated input current
9.4 A at 100 VAC
4.5 A at 200 VAC
3.8 A at 240 VDC for China
only
Table Continued
HPE 800W Flex Slot Platinum Hot-plug Power Supply
103
Summary of Contents for ProLiant DL360 Gen10
Page 27: ...Customer self repair 27 ...
Page 28: ...28 Customer self repair ...
Page 29: ...Customer self repair 29 ...
Page 30: ...30 Customer self repair ...
Page 35: ...Removing and replacing the bezel Removing and replacing the bezel 35 ...
Page 66: ...6 Remove the component SFF LFF 66 Removal and replacement procedures ...