![HP P9000 Reference Manual Download Page 353](http://html.mh-extra.com/html/hp/p9000/p9000_reference-manual_155959353.webp)
Table 155 REXX Variables Updated by YKQUERY Command with the TO Parameter Specified
(continued)
Copy direction: Reverse
1
Copy direction:
Forward
REXX variables
SECONDARY
specified
PRIMARY
specified
SECONDARY
specified
PRIMARY
specified
N
Y
N
Y
JNLState
N
Y
N
Y
ErrorCode
--
--
--
--
0
Pair
Y
Y
Y
Y
State
n
F
2
Y
4
Y
4
F
2
CTDelta
Y
F
2
F
2, 5
Y
MatchingPerCent
Y
Y
Y
Y
Reversed
F
2
Y
4
Y
4
F
2
CTTime
F
6, 7
Y
7
Y
7
F
6, 7
Diagnosis
1
Not applicable if the copy type is BC.
2
0
is set for the value because information cannot be acquired.
3
Null is set for the value because information cannot be acquired.
4
A value is set only if the copy type is TCA or CAJ, and the C/T group timer type is SYSTEM. If information cannot be
acquired, null is set for the value.
5
A value is set if the copy type is BC.
6
00
is set for the value.
7
If the copy type is BC or CA, null is set for the value because information cannot be acquired.
Legend:
Y: Updated
F: Updated to a fixed value
N: Not updated
--: Not applicable
REXX Variables Updated by the YKEWAIT Command with the TO Parameter Specified
Table 156 (page 353)
shows the copy group structure's REXX variables that are updated by the
YKEWAIT
command with the TO parameter specified. The table omits REXX variables that are not
affected by the
YKEWAIT
command.
Table 156 REXX Variables Updated by the YKEWAIT Command with the TO Parameter Specified
Copy direction: Reverse
Copy direction: Forward
REXX variables
SECONDARY
specified
PRIMARY
specified
SECONDARY
specified
PRIMARY
specified
Y
Y
Y
Y
SimplexCt
Y
Y
Y
Y
PendingCt
Y
Y
Y
Y
DuplexCt
Y
Y
Y
Y
TransitionCt
Y
Y
Y
Y
SuspendOpCt