![HP NonStop SSH 544701-014 Reference Manual Download Page 261](http://html.mh-extra.com/html/hp/nonstop-ssh-544701-014/nonstop-ssh-544701-014_reference-manual_165151261.webp)
HP NonStop SSH Reference Manual
STN Reference
•
261
zstn-evt-stop-process value is 1028
"<STN process name> STN window <2> stopping process <3> status <4>"
•
CAUSE: A dynamic session terminated and KILL_DYNAMIC is set to Y.
•
EFFECT: STN terminates the application which it started at the beginning of the session.
•
ACTION: None. Information only.
zstn-evt-param-license value is 1029
"<STN process name> STN using PARAM LICENSE <2>"
•
CAUSE: STN is starting up with PARAM LICENSE specified.
•
EFFECT: The specified license file is used instead of the default.
•
ACTION: None. Information only.
zstn-evt-license-pty-ok value is 1030
"<STN process name> STN will permit PTY/SSH sessions without a Telnet LICENSE"
•
CAUSE: See zstn-evt-license-exception value is 1004
•
EFFECT: See zstn-evt-license-exception value is 1004
•
ACTION: None. Informational only, to emphasize that PTY/SSH sessions are still allowed regardless of the
license exception.
zstn-evt-pool-used value is 1033
“ <$pname> STN Buffer pool used <2> <3>% , used=<4>kw size=<5>kw”
Indicates STN memory pool usage goes above 80%, or back down below 80%.
<2> is "OVER" or "UNDER"
<3> is the threshold percentage as sent by the POOL_WARNING command (default 80)
<4> is the current amount of memory used (unit=1024 words)
<5> is the total size of the pool (unit=1024 words) as configured by PARAM POOL_SIZE
Every minute STN checks the pool usage; if the percentage has changed from over to under the warning level, or under
to over, the EMS event is displayed. The EMS event is also displayed once at startup time. Due to fragmentation, usage
cannot reach 100%, and 80-90% is usually the maximum.
Use the POOL command to monitor pool usage. For larger configurations, increase PARAM POOL_SIZE.
zstn-evt-th-open-err value is 1034
"<1> Open TH <2> error <3>"
<1> - STN process name
<2> - Terminal Handler process name
<3> - Guardian open file error code
Summary of Contents for NonStop SSH 544701-014
Page 12: ...xii Contents HP NonStop SSH Reference Manual ...
Page 24: ...24 Preface HP NonStop SSH Reference Manual ...
Page 30: ...30 Introduction HP NonStop SSH Reference Manual ...
Page 46: ...46 Installation Quick Start HP NonStop SSH Reference Manual ...
Page 132: ...132 The SSH User Database HP NonStop SSH Reference Manual ...
Page 214: ...214 SSH and SFTP Client Reference HP NonStop SSH Reference Manual ...
Page 278: ...278 STN Reference HP NonStop SSH Reference Manual ...
Page 298: ...298 Monitoring and Auditing HP NonStop SSH Reference Manual ...
Page 302: ...302 Performance Considerations HP NonStop SSH Reference Manual ...